Regulatory; Front Panel Controls; Special Features And Options - Ametek California Instruments MX15 Series User Manual

Ac and dc power source
Table of Contents

Advertisement

Parameter
Installation/Over voltage
Category:
Pollution Degree:
Indoor Use Only
V ibration:
Shock:

2.4 Regulatory

Electromagnetic Emissions and
Immunity:
A coustic Noise:
Safety:

2.5 Front Panel Controls

Shuttle knob:
Decimal keypad:
Up/down arrow keys:
Function keys:
LCD display:
Status indicators:

2.6 Special Features and Options

M ode:
Parallel Operation:
Clock and Lock M ode:
(Option -LK M and -LK S required).
MX15 Series
ΙΙ
2
Designed to meet NSTA 1A transportation levels.
Designed to meet NSTA 1A transportation levels.
Designed to meet EN50081-2 and EN50082-2 European Emissions and Immunity
standards as required for the "CE" mark.
56 dBA maximum at 0% to 50% load, 68 dBA maximum greater than 50% load to
100% load. M easured at one meter.
Designed to EN 61010-1 European safety standards as required for the "CE" mark.
Controls:
A llows continuous change of all values including output calibration and range change.
A conventional decimal keypad facilitates quick entry of numerical values such as
voltage, current limit, etc. The large blue enter key will make the value you enter
effective. Using the SET key allows the user to preset all parameter values and update
them all at once by pressing the Enter key.
A set of up and down arrow keys is used to move the cursor position in all menus.
This allows quick selection of the desired function or parameter.
M easure key will display most measurement values. Program key will show all
program parameters. Output on/off key for output relay control. Phase key will
switch display to show program and measured values for each phase (not used on
M X 15).
Displays:
A two-line LCD display with backlight provides easy to read guidance through all
setup operations. A n adjustable viewing angle makes it easy to read from all practical
locations.
Bright status indicators inform the user of important power source conditions. The
Remote lamp informs the user that the unit is under remote control. The Overload
lamp indicates that excessive current is being drawn at the output. The Over
temperature lamp illuminates when internal heat sink temperatures are too high. The
Hi Range indicator is lit any time the unit is switched to the high voltage range. The
Output On/Off indicator is on when the power source output relays are closed.
Controller Features
This option is not available for the M X 15.
Up to three units can be paralleled in a single-phase configuration (with one master
controller and one or two auxiliary units). (M X 30/2 and M X 45/3). Only the master
unit requires a controller in this setup. The auxiliary units are controlled through the
system interface.
Up to three units (all with controllers) can be connected in a one, two, or three-phase
configuration using CLOCK and LOCK connections. Each unit requires its own
Specification
19