4.2.8
REGISTERS Menu
The registers menu provides access to the non-voltage setup storage of the power source. A
total of 16 front panel setups can be stored in registers numbered from 0 through 15. Each
register except register 0 can hold the complete front panel setup, including the programmed
transient list. This allows for quick recall of different setups and transient programs.
Register 0 is reserved to be used as the power-on setting as assigned by the user. To have the
power source start in a specific setting, save the desired setting to Register 0 and assign register
zero as the power-on default in the CONFIGURATION menu. Alternatively, the power source
can be set to power up with the RST factory default settings. See section 4.2.9 for factory default
settings.
ENTRY
SA V E
RECA LL
80
DESCRIPTION
REG 0 – 15
Saves the selected setup and transient list from memory.
(Setup only for Reg 0) The shuttle knob may be used to scroll
through the available list of setup register numbers.
Use the ENTER key to perform the save operation.
Register 0 can be assigned as the power-on state setup from
the CONFIGURA TION menu. A valid setup must be saved in
REG0 to do so.
Note that REG0 only saves the setup, not the transient list. A ll
other registers also save the transient list.
REG 0 – 15
Recalls the selected setup and transient list to memory. (Setup
only for Reg 0) The shuttle knob may be used to scroll through
the available list of setup register numbers.
Use the ENTER key to perform the recall operation.
Register 0 can be assigned as the power-on state setup from
the CONFIGURA TION menu. A valid setup must be saved in
REG0 to do so.
Note that REG0 only saves the setup, not the transient list. A ll
other registers also save the transient list.