2.7 Supplemental Specifications

Supplemental specifications are not warranted and generally reflect typical performance
characteristics. These characteristics have been checked on a type test basis only and are not
verified on each unit shipped. They are provided for reference only.
2.7.1
Output
Output Parameter
Slew rate:
Stability:
Settling time:
Temperature coefficient:
Stability:
Constant Power M ode:
2.7.2
Acoustic Noise Levels
A coustic Noise:
Front
Back
MX15 Series
MX15
Voltage:
> 0.5 V /micro sec
0.25 % over 24 hour period at constant line, load and temperature.
< 0.5 msec
Frequency:
± 5ppm per degree C
± 15 ppm per year
Current:
Operation at higher currents but constant power is possible from 80% of V oltage range
(125% of max. current) declining to 100% of maximum current at 100 % of voltage range
for short periods of time or at reduced ambient temperatures. (< 15 mins @ 30° C). See
Figure 2-2 and Figure 2-4.
M easured at a distance of one meter. (3 ft.)
53 dBA at no load to 65 dBA at full load.
55 dBA at no load to 67 dBA at full load