3.3 Mechanical Installation

The MX's are completely self-contained power sources. They are to be used free standing on a
solid surface. The units are fan cooled, drawing air in from the front and exhausting at the rear.
The front and back of each unit must be kept clear of obstruction and a 6" clearance must be
maintained to the rear. Special consideration of overall airflow characteristics and the resultant
internal heat rise must be considered at all times to avoid self-heating and over temperature
problems.

3.4 AC Input Connections and Wiring

Three-phase Delta or Y AC input voltage of sufficient amperage (consult AC input specifications
for maximum AC current per phase) is required to power the MX Series.
Note:
AC power should be routed through a properly sized and rated three-phase
PROTECTIVE CIRCUIT BREAKER or similar branch circuit protection device with
disconnect capability. This will protect building wiring and other circuits from
possible damage or shutdown in case of a system problem. It will also facilitate
removing AC input power to the MX system in case of service or reconfiguration
requirements.
Note:
AC input wiring and connections must conform to local electrical safety codes
that apply. Always consult a qualified electrician prior to installation of any MX
System.
AC input connections are to be made directly to the input fuse block. The input fuse block is
located on the lower right-hand corner of the back of the MX15 chassis. To access the input
fuse connection block, the protective rear cover needs to be removed first.
CAUTION:
No wiring for AC input connections is provided with the MX Series and must be provided by the
end user or installer. Input wiring should be entered through the right-hand side (when facing the
back of the MX cabinet, see Figure 3-4) wire access opening located at the rear bottom of the
MX15 chassis.
MX15 Series
Always check the input rating on the model number tag before
connecting AC input power. Consult factory if input settings
have to be changed.
Always disconnect any input power completely when removing
any protective cover and allow the internal capacitors to fully
discharge (minimum of 15 mins) before removing any cover.
See Figure 3-2 for details.