Specifications - Olympus STM7 Instructions Manual

Measuring microscope
Table of Contents

Advertisement

8 8

Specifications

Frame
Item
(Small manual
Vertical movement range
Maximum measurable
height
Z-axis measurement
range
Z-axis measurement
resolution
Z-axis load
Weight of
standard
weight
combination
(Modules
included)
Maximum
loading
weight
Z-axis drive method
Reference movement distance per turn of fine
Reference movement distance per turn of coarse
Hand switch
The operations are available at hand by using 11
buttons, e.g. LED SEL buttons, counter data reset
buttons, etc.
Focus controller
Transmitted light
· Light guide : Green LED for transmitted light illumination
illumination
Rating
STM7-CB/STM7-CBA: Refer to the instruction manual provided with the control box STM7-CB/STM7-
MM6-ILPS-2:
Applicable fuses
Dimensions (between
427(W)x547(D)
x651(H) mm
center positions of
(When combined
axes of stage)
with STM7-CS100)
Frame weight
Control box weight
STM7-SF
STM7-MF
(Middle manual
frame)
frame)
175 mm
175 mm
120 mm (with measurement
objective)
, 175 mm (with
*1
metallurgical objective)
*1
10.6 kg
(Camera, U-TV1XC, STM7-FN, MM6-ETR,
MM6C-RLAS, revolving nosepiece,
5 objectives, filter)
11 kg
*3
Manual coaxial fine/coarse focusing knobs
focusing knob: 0.2 mm
focusing knob: 36. 7 mm
Dominant wavelength: Max:550 nm, Min:520 nm
Dimensions:
Weight:
Average life:
CBA.
Refer to the instruction manual provided with the power supply unit MM6-ILPS-2.
T5A(H)250V (LITTELFUSE 0215005.MXP)
606(W)x727(D)
x651(H) mm
(When combined
with STM7-CS200)
51.8 kg
77.1 kg
Approx. 4.9 kg (STM7-CB) / Approx. 5.4 kg (STM7-CBA)
*1 When STM7-SF/STM7-SFA is combined with STM7-CS50, subtract 15mm.
*2 The height of the specimen which can be placed at the position more than ±180 mm farther
from the center of measurement (light axis) in the X- or Y-axis direction is 100 mm or less.
*3 If you want to load those other than the standard combinations, contact Olympus.
Specifications
STM7-LF
STM7-SFA
(Large manual
(Small motorized
frame)
frame)
145 mm
175 mm
90 mm
120 mm (with measurement
(with
measurement
objective)
objective)
*2
,
metallurgical objective)
145 mm (with
metallurgical
objective)
*2
0.1 μm
(Camera, U-TV1XC, STM7-AF, MM6-ETR,
MM6C-RLAS, revolving nosepiece, 5 objectives)
· The operations are available at hand by using
17 buttons, e.g. FOCUS button, AF START/STOP
button, etc and fine/coarse focusing knob.
· Coarse movement speed : 8 mm/sec. (max.)
· Movement distance (guide for per turn) of fine/
coarse focusing knob can be selected from 4
values:
800 μm, 400 μm, 100 μm, 50 μm
Ø24x81.7 mm (cable length 1500 mm)
80 g
Approx. 30000 hours (Ambient temperature 20 °C, light
intensity level 50%)
805(W)x1025(D)
427(W)x547(D)
x684(H) mm
x811(H) mm
(When combined
(When combined
with STM7-CS300)
with STM7-CS100)
150.5 kg
53.8 kg
STM7-MFA
STM7-LFA
(Middle
(Large motorized
motorized frame)
frame)
175 mm
145 mm
90 mm
, 175 mm (with
measurement
*1
objective)
*1
145 mm (with
metallurgical
objective)
12.8 kg
15 kg
*3
Motorized
606(W)x727(D)
805(W)x1025(D)
x811(H) mm
x844(H) mm
(When combined
(When combined
with STM7-CS200)
with STM7-CS300)
78.6 kg
152 kg
STM7
(with
*2
,
*2
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents