3. When the coarse focusing knob is rotated, the fine focusing knob is
rotated together with it. Do not stop rotating the fine focusing knob
or rotate it in the reverse direction. Errors may be caused.
Controller
1. The controller data may become unexpectedly corrupted, so make
frequent backups of your data.
2. Olympus shall have no liability for any damage (including
compensation for the corrupted controller data) from the use or
misuse of this product.
3. Microsoft Windows has been installed on the controller of this system.
Backup and keep the system data in a safe place (Olympus does not
provide support for backing up your system data).
For more information about the controller and Microsoft Windows ,
refer to their corresponding manuals.
4. When themes other than standards are set on the Windows desktop,
the software window may not be displayed or printed properly.
5. The operations of the controller other than the controllers of which
operations were confirmed are not ensured. For the controllers of
which operations were confirmed, contact Olympus.
6. If this system is used with connecting to the network, the data
import may fail or the system could not be operated properly due to
the automatic update of the operating system, etc.
Disable the automatic update of the operating system, etc. before
use. If you update the operating system, etc. confirm the condition of
this system in advance.
7.
If a virus search, sleep or the screen saver is activated while the
system is operating, data import could fail and the system operation
could become unstable. Disable an automatic virus search, sleep
and the screen saver (these functions have been disabled when the
basic software is installed).
8. The system does not support to change the location of the
controller. (Use the operating system with the factory default
language: Japanese or English.)
Basic software/MIA, EFI option software
} Refer to the instruction manual provided with the basic software/
MIA, EFI option software.
Excel transfer tool
1. The Excel transfer tool and the basic software can be installed to
the same controller, but they cannot be used at the same time.
2. The Excel transfer tool cannot be used with STM6.
Focus navigator unit
1. The focus navigator unit cannot be used together with the
autofocus unit STM7-AF.
2. The objectives compatible with this unit are the 10X to 50X
objectives.
STM7
9