Enable/disable of interlock between coded revolving nosepiece and illumination
Set whether or not to interlock the illumination ON/OFF status and the light intensity values with the switching of the
coded revolving nosepiece.
Setting items
Not interlocked
Interlocked
Output of counter data when LASER LED of the autofocus unit is turned ON
When using the autofocus unit STM7-AF and the LASER LED is turned ON, set functions when the DATA/HALF button of
the focus controller STM7-MCZ is pressed.
The counter data is outputted.
After AF is performed successfully, the counter data is outputted.
*2 If the autofocus is not performed successfully, the counter data is not outputted.
Origin search at startup
Set whether or not to search the origin when you start the microscope.
Setting items
Main switch " " (ON): The origin is not searched.
Main switch " " (ON): The origin is searched.
*3 Even though the lower software limit is set during operation, the setting value of the lower software limit is not saved
if the main switch is set to " " (OFF).
*4 When the lower software limit is set, the setting value is saved and even though the main switch is set to " " (OFF),
the setting value is kept. While the lower software limit is set, if the main switch is set to " " (OFF) and set to " " (ON)
again, the lower software limit setting is ON automatically after the origin is searched. While the lower software limit
setting is cancelled, if the main switch is set to " " (OFF), the lower software limit will not be set when the main
switch is set to " " (ON) again.
} The origin search refers to the operation of moving the Z-axis to the upper limit within the Z-axis movable area.
} When the origin search is set, the Z-axis moves up to the upper limit within the Z-axis movable area immediately after the
main switch is set to " " (ON). Make sure that the cables are not caught in anything before setting the main switch to " " (ON).
} When the origin search execution is set, the origin search is also executed after termination of the user Setup mode.
} When RS-232C communication equipment is connected, please start RS-232C communication equipment after
STM7 ends the origin search.