10.1.1

Applications

The measuring device described in this Operating Manual is to be used only for measuring the flow
rate of conductive liquids in closed pipes.
A minimum conductivity of 20 µS/cm is required for measuring demineralized water. Most liquids
can be metered, provided they have a minimum conductivity of 5 µS/cm, for example:
• acids, alkalis, pastes, mashes, pulps,
• drinking water, wastewater, sewage sludge,
• milk, beer, wine, mineral water, yogurt, molasses, etc.
Resulting from incorrect use or from use other than that designated, the operational safety of the
measuring devices can be suspended. The manufacturer accepts no liability for damages being
produced from this.
Liner specific applications:
• Promag W (DN 25 to 2000):
– Polyurethane lining for applications with cold water and for slightly abrasive fluids,
– Hard rubber lining for all applications with water (especially for drinking water).
• Promag P (DN 15 to 600):
– PTFE lining for standard applications in chemical and process industries,
– PFA lining for all applications in chemical and process industries; especially for high process
temperatures and applications with temperature shocks.
• Promag H (DN 2 to 100):
PFA lining for all applications in chemical, process and food industries; especially for high process
temperatures, for applications with temperature shocks and for applications with CIP or SIP
cleaning processes.
10.1.2

Function and system design

Electromagnetic flow measurement on the basis of Faraday's Law.
The flow measuring system consists of the following components:
• Promag 53 transmitter
• Promag W, Promag P or Promag H sensor
Two versions are available:
• Compact version: transmitter and sensor form a single mechanical unit.
• Remote version: transmitter and sensor are installed separately.
10.1.3

Input variables

Flow rate (proportional to induced voltage)
Typically v = 0.01 to 10 m/s with the specified measuring accuracy
Over 1000 : 1
Status input (auxiliary input):
U = 3 to 30 V DC, R
= 3 kΩ, galvanically isolated.
i
Switch level: ±3 to ±30 VDC, independent of polarity
Proline Promag 53 PROFIBUS DP/PA
Endress+Hauser

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFI BUS Proline Promag 53 PROFIBUS DP and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Profi bus proline promag 53 profibus pa

Table of Contents