Endress+Hauser PROFI BUS Proline Promag 53 PROFIBUS DP Operating Manual page 25

Electromagnetic flow measuring system
Table of Contents

Advertisement

Proline Promag 53 PROFIBUS DP/PA
Endress+Hauser
Promag P
Flow rate characteristic values - Promag P (SI units)
Nominal
Recommended flow rate
diameter
Min./max. full scale value
(v ≈ 0.3 or 10 m/s)
[mm]
[inch]
15
½"
4 to 100 dm3/min
25
1"
9 to 300 dm3/min
32
1 ¼"
15 to 500 dm3/min
40
1 ½"
25 to 700 dm3/min
50
2"
35 to 1100 dm3/min
65
2 ½"
60 to 2000 dm3/min
80
3"
90 to 3000 dm3/min
100
4"
145 to 4700 dm3/min
125
5"
220 to 7500 dm3/min
150
6"
20 to 600 m
200
8"
35 to 1100 m
250
10"
55 to 1700 m
300
12"
80 to 2400 m
350
14"
110 to 3300 m
400
16"
140 to 4200 m
450
18"
180 to 5400 m
500
20"
220 to 6600 m
600
24"
310 to 9600 m
Full scale value
(v ≈ 2.5 m/s)
25 dm3/min
75 dm3/min
125 dm3/min
200 dm3/min
300 dm3/min
500 dm3/min
750 dm3/min
1200 dm3/min
1850 dm3/min
3
3
/h
150 m
/h
3
3
/h
300 m
/h
3
3
/h
500 m
/h
3
3
/h
750 m
/h
3
3
/h
1000 m
/h
3
3
/h
1200 m
/h
3
3
/h
1500 m
/h
3
3
/h
2000 m
/h
3
3
/h
2500 m
/h
Installation
Factory settings
Pulse value
Low flow cut off
(v ≈ 0.04 m/s)
(≈ 2 pulse/s)
0.20 dm3
0.5 dm3/min
0.50 dm3
1 dm3/min
1.00 dm3
2 dm3/min
1.50 dm3
3 dm3/min
2.50 dm3
5 dm3/min
5.00 dm3
8 dm3/min
5.00 dm3
12 dm3/min
10.00 dm3
20 dm3/min
15.00 dm3
30 dm3/min
3
3
0.025 m
2.5 m
3
3
0.05 m
5.0 m
3
3
0.05 m
7.5 m
3
3
0.10 m
10 m
3
3
0.10 m
15 m
3
3
0.15 m
20 m
3
3
0.25 m
25 m
3
3
0.25 m
30 m
3
3
0.30 m
40 m
/h
/h
/h
/h
/h
/h
/h
/h
/h
25

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFI BUS Proline Promag 53 PROFIBUS DP and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Profi bus proline promag 53 profibus pa

Table of Contents