Interrupt Requests - Renesas R8C Series User Manual

16-bit single-chip microcomputer
Hide thumbs Also See for R8C Series:
Table of Contents

Advertisement

R8C/1A Group, R8C/1B Group
16.2.3

Interrupt Requests

Clock synchronous serial I/O with chip select has five interrupt requests: transmit data empty, transmit end,
receive data full, overrun error, and conflict error. Since these interrupt requests are assigned to the clock
synchronous serial I/O with chip select interrupt vector table, determining interrupt sources by flags is required.
Table 16.3 shows the Clock Synchronous Serial I/O with Chip Select Interrupt Requests.
Table 16.3
Clock Synchronous Serial I/O with Chip Select Interrupt Requests
Interrupt Request
Transmit data empty
Transmit end
Receive data full
Overrun error
Conflict error
CEIE, RIE, TEIE, and TIE: Bits in SSER register
ORER, RDRF, TEND, and TDRE: Bits in SSSR register
If the generation conditions in Table 16.3 are met, a clock synchronous serial I/O with chip select interrupt request
is generated. Set each interrupt source to 0 by a clock synchronous serial I/O with chip select interrupt routine.
However, the TDRE and TEND bits are automatically set to 0 by writing transmit data to the SSTDR register and
the RDRF bit is automatically set to 0 by reading the SSRDR register. In particular, the TDRE bit is set to 1 (data
transmitted from registers SSTDR to SSTRSR) at the same time transmit data is written to the SSTDR register.
Setting the TDRE bit to 0 (data not transmitted from registers SSTDR to SSTRSR) can cause an additional byte of
data to be transmitted.
Rev.1.30
Dec 08, 2006
REJ09B0252-0130
Abbreviation
TXI
TEI
RXI
OEI
CEI
Page 182 of 315
16. Clock Synchronous Serial Interface
Generation Condition
TIE = 1, TDRE = 1
TEIE = 1, TEND = 1
RIE = 1, RDRF = 1
RIE = 1, ORER = 1
CEIE = 1, CE = 1

Advertisement