7.1

VCC Input Voltage

7.1.1

Monitoring Vdet1

Vdet1 cannot be monitored.
7.1.2

Monitoring Vdet2

Set the VCA27 bit in the VCA2 register to 1 (voltage detection 2 circuit enabled). After td(E-A) has elapsed
(refer to 19. Electrical Characteristics), Vdet2 can be monitored by the VCA13 bit in the VCA1 register.
7.1.3

Digital Filter

A digital filter can be used for monitoring the VCC input voltage. When the VW1C1 bit in the VW1C register
is set to 0 (digital filter enabled) for the voltage monitor 1 circuit and the VW2C1 bit in the VW2C register is set
to 0 (digital filter enabled) for the voltage monitor 2 circuit, the digital filter circuit is enabled.
fRING-S divided by 1, 2, 4, or 8 may be selected as a sampling clock.
The level of VCC input voltage is sampled every sampling clock cycle, and when the sampled input level
matches two times, the internal reset signal changes to "L" or a voltage monitor 2 interrupt request is generated.