SpycerNode
Sideplane
Sideplane
OK/Power
fault (amber)
(green)
On
Off
X
On
On
X
Off
X
On
Off
* The Activity bar graph is a 6-segment drive activity meter, showing activity of the
SAS interface to the sideplane. For zero activity, no segments are lit, scaling lineary
until all segments are lit when the interface is transferring data at full capacity.
X = Disregard

Drives

Drives are provided with dual interfaces and these are connected into sepa-
rate storage domains. Therefore a fault in one controller does not prevent
the other from operating.
All drives are dual ported, so more than one initiator will be communicating
with the device at any point in time. All drives therefore support SCSI reser-
vations. This is a method to allow a controller to "own" access to a given
device, reserving it for its exclusive use.
All drives provide error detection and correction capabilities. These are
reported to the application in line with the SCSI specifications.
Drive mapping for 2U12
User Manual | 2902.3266.02 - 08
Logical
Cable fault
fault
(amber)
(amber)
Off
Off
X
X
On
X
X
On
Off
Off
The order of the hard drives in an enclosure is
virtualized, and may bear no resemblance to the order shown here.
01
02
05
06
09
10
Product Description
The Front of the System
Activity bar
Status
graph
(green)
X
Sideplane card OK/Ppower
good
Off
Sideplane card fault
X
Drive fault (host indicated)
Off
Cable fault
On*
Drive activity
03
07
11
04
08
12
23