General Notes; Enclosures - R&S SpycerNode 2U12 User Manual

Table of Contents

Advertisement

SpycerNode

General Notes

Please observe the following general important notes:
● Do not lift the enclosure by the handles on the rear modules or the
PCMs. They are not designed to take the weight. Only lift from under-
neath the main chassis.
● If this equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
● The optional RJ45 socket on the I/O module, it is for Ethernet connection
only and must not be connected to a telecommunications network.
● All plug-in modules and blank plates are part of the fire enclosure and
must only be removed when a replacement can be immediately added.
The system must not be run without all modules or blanks in place.
● Unplug the unit before you move it or if you think it has become
damaged in any way.
● The plug on the power supply cord is used as the main disconnect
device. Ensure that the socket outlets are located near the equipment
and are easily accessible.
● When powered by multiple AC sources, disconnect all supply power for
complete isolation.
● In order to comply with applicable safety, emission and thermal require-
ments no covers should be removed and all bays must be populated with
plug-in modules or blanks.
● The power connection should always be disconnected prior to removal of
a PCM/PSU from the enclosure.
● A safe electrical earth connection must be provided to the power supply
cords. Check the grounding of the enclosure before applying power.
● Provide a suitable power source with electrical overload protection to
meet the requirements laid down in the technical specification.
● Do not remove PCMs, Cooling Modules, PSUs or I/O Modules unless
you have a replacement model of the correct type ready for insertion.
● Connect the system to an uninterruptible power supply redundantly on
two phases.
● It is recommended that you fit and check a suitable anti-static wrist or
ankle strap and observe all conventional ESD precautions when
handling plug-in modules and components. Avoid contact with backplane
components and module connectors, etc.
2U Enclosures
Please observe the following general important notes:
● An enclosure can weigh up to to 26 kg (57lb) depending on configura-
tion. Do not try to lift the enclosure by yourself.
● It is advisable to remove all plug-in modules to minimize weight before
lifting the enclosure.
● The enclosure must only be operated from a power supply input voltage
range of 100-240 VAC.
User Manual | 2902.3266.02 - 08
Safety
General Notes
11

Advertisement

Table of Contents
loading

Table of Contents