Enclosure - R&S SpycerNode 2U12 User Manual

Table of Contents

Advertisement

Safety
General Notes
● When bifurcated power cords ('Y' leads) are used, they must only be
connected to a supply range of 200-240 V.
● A faulty PCM must be replaced with a fully operational module within 24
hours.
5U Enclosure
Please observe the following general important notes:
● Important: The enclosure must be mounted in a rack.
● An unpopulated enclosure can weigh up to 45kg (100lb). Use appro-
priate lifting methods.
● A fully populated enclosure weighs 135kg (298lb). Only lift the enclosure
when the drawers are empty and latched closed. Do not attempt to lift
the enclosure when populated with drives.
● When closing the drawers, do so firmly, ensuring the latches are
engaged.
● Do not attempt to disassemble the rear sub-chassis from the enclosure.
● Operating temperatures inside the enclosure drawers can reach up to
60°C. Take care when opening drawers and removing drive carriers.
● If any component of the product fails, consult your storage vendor.
● For North American use, each branch circuit must be rated for 20A.
● The equipment is suitable for connection to an IT power system
(Norway), when mounted in a Restricted Access Location where equipo-
tential bonding has been applied by a service person.
● Double pole/neutral fusing in PSUs.
● Risk of explosion if the battery within the RAID controller is replaced with
an incorrect type. Dispose of used batteries according to the instructions.
There are no user serviceable parts within the RAID controller.
● Due to product acoustics it is recommended that users wear ear protec-
tion for any prolonged exposure.
● To prevent over-turning, drawer interlocks stop users from opening both
drawers at the same time. Do not attempt to force open a drawer when
the other drawer is already open.
● The product ratings are: voltage: 200 to 240 VAC; current: 16A or 13A
per inlet; frequency: 50 to 60 Hz. This information can also be found on
the back of the PSUs.
12
SpycerNode
User Manual | 2902.3266.02 - 08

Advertisement

Table of Contents
loading

Table of Contents