3.9

DLMS over PRIME Test

3.9.1

Features

BN tool executes cycle reading test by connecting to ZIV DCU (PRIME v1.3.6).
3.9.2

Network Setting

(1) Power ON the G-CPX3 board of Base Node.
(2) Connect G-CPX3 board to host PC with USB cable.
(3) Connect host PC to DCU with LAN cable.
(4) Connect G-CPX3 board to Power Line.
(5) Push Reset Button on the G-CPX3 board.
(6) Execute "prime14_cpx3_pc_bn_RevXXX.exe".
(7) Configure BN by "Settings" menu before connecting to COM Port. "DCU Connect"->"On" should be
set. DCU port number should be configured by "DCU Connect"->"Port setting"
R11UM0156EJ0240 Rev.2.40