Table 4.2 Operating Conditions
Parameter
Power supply
Power consumption
Input voltage high
Input voltage low
Input voltage high (/RESET)
Input voltage low (/RESET)
Output voltage high
Output voltage low
Output current low
Output current high
Operating temperature
All further specifications and statements of timing assume the application of the above-
mentioned operating conditions.
Functional Earth and Shielding
4.3
The shield of R-IN32M3 Module is internally connected with GND via a RC-combination.
Connect the shield to the frame ground (FG) for electrical testing to obtain CE marking.
Shock and Vibration
4.4
Vibration Test
4.4.1
20 to 2,000 to 20 Hz, amplitude 5 G (max.)
Sweep 4 min.
IEC 60068-2-64
Shock Test
4.4.2
50 G, 6 mS, X1/X2/Y1/Y2/Z1/Z2 direction, 3 times
IEC 60068-2-27
Drop Test
4.4.3
For packing condition (delivery box) JIS Z 0200
JIS Z 0200/ISO 4180
R19UH0111ED0100 Rev.1.00
June 30, 2020
Symbol
Vcc
P
VIH
VIL
VIH
RESET
VIL
RESET
VOH
VOL
IOL
IOH
T
a
X/Y/Z direction, 4 times
Min.
Typ.
3.15
3.3
1.3
2.0
-0.3
2.2
-0.2
Vcc - 0.1
6
-6
-40
4.
Electrical Characteristics
Max.
Unit
3.45
V
2.0
W
Vcc + 0.3
V
0.8
V
Vcc
V
0.3
V
V
0.1
V
mA
mA
70
°C
Page 21 of 41