Data Transmission Test - Renesas R9A06G037 User Manual

Prime v1.4 base node tool
Table of Contents

Advertisement

PRIME v1.4 Base Node Tool
User Manual
3.3

Data Transmission Test

"prime14_cpx3_pc_bn_RevXXX.exe" has several parameters for Transmission test. There are 3
transmission types (CON.TYPE=NULL SSCS / IEC432 SSCS / AppEmu / IPv6).
-
Null / IEC432 / AppEmu / IPv6 specifies the CON.TYPE field of CON control packet which
transmitted from Base Node. (Please refer to 3.16 for details on the settings for operating in IPv6
mode.)
- Unicast / Multicast specifies the addressing type. (AppEmu mode and IPv6 mode are limited to
Unicast.)
- Modulation specifies a modulation type of each data-packet. "AUTO" means that modulation is
updated according to the robustness management.
- Data length specifies the length of data packet in byte (MIN 2 bytes / MAX 1270 bytes).
- Data specifies a transmission data which any file has been selected by user. When this field is
specified no file, then this application will send a data which is incremented number from 0.
- Priority is specified in PRIME spec and it specifies the timing of sending data to Power Line.
(Recommended value is 3).
- ACK mode specifies transfer mode (Application level). This is a limited function between Renesas
Base Node and Service Node. (This is not supported on AppEmu mode.)
- Request length is only valid when ACK = Data request. (This is not supported on AppEmu mode.)
- Number of trans specifies transfer times.
- Time reference specifies the type of Time Reference sub header.
- Edit TREF Params specifies the parameters of Time Reference sub header (setting dialog pops
up). This setting is enabled only when "Cert" or "Fix" is selected for TREF.
- APPEMU specifies the options for AppEmu cycle test execution. These are only activated when
AppEmu for CON.TYPE is selected.
- ARQ is specified in PRIME spec. It enables Automatic Repeat Request (MAC level).
(ACK/NACK is reported from receiver to sender for each data packet) (This is not supported on
AppEmu mode.)
- AE Enable is specified in PRIME spec. It enables authentication and encryption on the data sent.
(This is supported on SP1 or SP2.)
R11UM0156EJ0240 Rev.2.40
Jul. 28, 2020
Renesas Electronics Group Confidential
.
3
PC Tool operation procedure
PRELIMINARY
Notice This is not a final specification. Some
parametric limits are Subject to change.
Page 18 of 82

Advertisement

Table of Contents
loading

Table of Contents