Bn Gateway Address; Data Type For Transmission Data; Connection Settings - Renesas R9A06G037 User Manual

Prime v1.4 base node tool
Table of Contents

Advertisement

PRIME v1.4 Base Node Tool
User Manual
Figure 3.63 "IPv6 SSCS Data Settings" dialog and "Context Table" dialog
3.16.2

BN Gateway Address

The default gateway address of the BN tool is a link-local address that is
"Modified EUI-64" as an interface ID. In addition to this default gateway address, the BN
network ID and
tool can use another gateway address too. If user want to use another gateway address, set the address
to the "BN Gateway Address" box. If not set to this box, the BN tool use only the default gateway
address.
3.16.3

Data Type for transmission data

In the case of CON.TYPE
IPv6 packet format before sending it. Whether or not to convert the transmission data specifies in the
"Data Type". This setting applies to the data sending with "Data Transmission (see 3.3)" and
"Data.request (see 3.15)".
- If the "RAW Data" is selected, the data will be sent without any changes. In this setting, the IPv6
packet header is not created, and the data is treated as the payload of MAC_DATA.request
primitive (see PRIME 4.5.4.2).
- If the "Configured Data" is selected, the data will be sent with any changes. In this setting, the IPv6
packet
header
CL_IPv6_DATA.request (see PRIME 5.6.9.5.2).
3.16.4

Connection Settings

- "Header Compression" specifies the compression method standardized by PRIME (see PRIME
5.6.8.4.2). These compression methods are as follows.
"DATA.HC=0" does not apply compression. However, if the stateless address compression
-
method is supported, the stateless address compression method is applied even if
"DATA.HC=0" is specified.
"DATA.HC=1" apply the address compression method of LOWPAN_NH.
-
"DATA.HC=2" apply the stateful address compression method.
-
"DATA.HC=3" apply the address compression method of LOWPAN_NH and the stateful
-
R11UM0156EJ0240 Rev.2.40
Jul. 28, 2020
=IPv6, the BN tool converts the transmission data specified by user into the
is
created,
and
Renesas Electronics Group Confidential
the
converted
data
Notice This is not a final specification. Some
parametric limits are Subject to change.
.
3
PC Tool operation procedure
composed of
is
treated
as
IPv6_PDU
PRELIMINARY
fe80::/64
as a
of
Page 68 of 82