Renesas R9A06G037 User Manual page 30

Prime v1.4 base node tool
Table of Contents

Advertisement

PRIME v1.4 Base Node Tool
User Manual
3.6.2.2
AppEmu cycle test data
Table 3-6 shows the execution of each step in AppEmu cycle test by the PRIME network version. For
PRIME v1.4 and v1.3.6 network all steps are executed. For PRIME v1.4 BC network, some data
transmissions in Step 4 and 5 are skipped. Because the maximum payload size of PHY type BC frame
for PRIME v1.4 BC is 76 bytes, the large data cannot be transmitted. Although BN tool uses BC mode:
"On (v1.3.6)" for v1.3.6 network, it does not use any robust modulations (DBPSKR-R and DQPSK-R)
and the maximum payload size of the frame is large enough to transmit data for all steps.
Table 3-6 The execution of each step by the PRIME network.
Size of packet
payload [bytes]
request
Step 2
24
Step 3
24
Step 4
75
16
Step 5
17
29
65
137
209
R11UM0156EJ0240 Rev.2.40
Jul. 28, 2020
v1.4
response
(BC mode: Off)
36
Yes
31
Yes
138
Yes
52
Yes
17
Yes
29
Yes
65
Yes
137
Yes
209
Yes
Renesas Electronics Group Confidential
.
3
PC Tool operation procedure
Execution of the step
v1.4 BC
(BC mode: On)
Yes
Yes
No
Yes
Yes
Yes
No
No
No
PRELIMINARY
Notice This is not a final specification. Some
parametric limits are Subject to change.
v1.3.6
(BC mode: On
(v1.3.6))
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 30 of 82