All Matrix 120 models can be connected to a CBX connection box through the
CAB-1011 accessory cable. Th
connector on the Matrix 120 side and in a 25-pin male D-sub connector on the
CBX side.
Do not use CAB-DSxx-S accessory cables with Matrix 120.
CAUTION
We recommend making system connections through one of the CBX connection
boxes since they offer the advantages of easy connection, easy device
replacement, opto-isolated inputs (External Trigger and Input 2) and outputs
(Outputs 1 and 2), and filtered reference signals.
If you require direct wiring to the reader the connections are the same as shown in
Appendix A .
NOTE
The table below gives the pinout of the CBX100/500 terminal block connectors.
Use this pinout when the Matrix 120 reader is connected by means of the
CBX100/500:
Input Power
Inputs
54

CBX Electrical Connections

Group
Label
Vdc
GND
Earth
+V
I1A
I1B
-V
+V
I2A
I2B
-V
i
s accessory cable terminates in an M12 17-pin
Power Supply Input Voltage +
Power Supply Input Voltage -
Protection Earth Ground
Power Source - External Trigger
External Trigger A (polarity insensitive)
External Trigger B (polarity insensitive)
Power Reference - External Trigger
Power Source - Inputs
Input 2 A (polarity insensitive)
Input 2 B (polarity insensitive)
Power Reference - Inputs