Electrical Features

Power
Supply Voltage
Consumption
Communication Interfaces
Main: RS232, RS422 Full-duplex
USB
Ethernet (Built-in)
supported application protocols
Fieldbus
Inputs
Input 1(External Trigger) and Input 2
Max. Voltage
Max. Input Current
a
Outputs
Output 1 and 2
V
I
OUT high (
LOAD = 100 mA) Max.
V
I
OUT low (
LOAD = 100 mA) Max.
I
LOAD Max.
a. when connected to the CBX connection boxes the electrical features for Output 1 and 2 become the following:
Opto-isolated; V
CE
V
= 1 Vdc max. @ 10 mA; P
CE saturation
154
= 30 Vdc max.; I
= 40 mA continuous max.; 130 mA pulsed max.;
CE
= 90 mW Max. @ 50 °C ambient temp.
D

Technical Features

5 to 30 Vdc
(10 to 30 Vdc with CBX)
0.4 to 0.1 A
2400 to 115200 bit/s
USB 2.0 Hi-Speed
10/100 Mbit/s
TCP/IP, EtherNet/IP, Modbus TCP, PROFINET-IO
CBX500 with HMS Host Interface Modules
short circuit protected
(opto-isolated and polarity insensitive when connected
through CBX)
3.5 mA (24 mA max when connected through CBX)
NPN or PNP short circuit protected
(opto-isolated and polarity sensitive when connected
through CBX)
28.3 Vdc (when using 30 Vdc power supply)
Chapter 10
30 Vdc
1.7 Vdc
145 mA