6
6

TECHNICAL FEATURES

ELECTRICAL FEATURES
Supply voltage
Power consumption
Interfaces
LED Indicators
OPTICAL FEATURES
Sensor
Max read rate
Reading field
Max. resolution
ENVIRONMENTAL FEATURES
Working temperature
Storage temperature
READING FEATURES
Readable codes:
MECHANICAL FEATURES
Dimensions (LxWxH)
114
5 Vdc ± 5%
RS232, Wedge, PEN Emulation
Power ON / Power OFF / Good Read / Miss
CCD solid state
270 read/sec
See diagrams on page 115
0.076 mm (3 mils)
0° to +40 °C / +32° to +104 °F
-20° to +70 °C / -4° to +158 °F
EAN/UPC
2/5 family
Code 128
EAN 128
ISBT 128
Pharmaceutical codes
Telepen (TC1100-x100 only)
MSI (TC1100-x100 only)
Plessey (TC1100-x100 only)
Delta IBM
Code 16K
Pharmacode (TC1100-x100 only)
Codablock-A (TC1100-x200 only)
Codablock-F Std (TC1100-x200 only)
Codablock-F EAN (TC1100-x200 only)
PDF417 (TC1100-x200 only)
60.5 x 63 x 27 mm / 2.38 x 2.48 x 1.06 in
1.5 W
Read
Code 39
Codabar
Code 93
Code 49
TC1100