Honeywell XENON 1902 User Manual

Honeywell XENON 1902 User Manual

Area-imaging scanner
Hide thumbs Also See for XENON 1902:
Table of Contents

Advertisement

Quick Links

Xenon™ 1900/1902
Area-Imaging Scanner
User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell XENON 1902

  • Page 1 Xenon™ 1900/1902 Area-Imaging Scanner User’s Guide ™...
  • Page 2 Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in speci- fications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not repre- sent a commitment on the part of HII.
  • Page 3 The user may find the fol- lowing booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Honeywell is not responsible for any radio or television interference caused by unauthorized modifications of this equip- ment or the substitution or attachment of connecting cables and equipment other than those specified by Honeywell.
  • Page 4 Nijverheidsweg 9-13 5627 BT Eindhoven The Netherlands Honeywell International Inc. shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive.
  • Page 5 In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those sys- tems will reuse or recycle most of the materials of the product you are dis- posing in a sound way.
  • Page 6: Laser Safety Statement

    Russia Gost-R certificate South Korea This product meets Korean agency approval. Taiwan If the following label is attached to your product, the product meets Taiwan agency approval: BSMI Standard: CNS13438, CNS14336 依據標準 : CNS13438, CNS14336 International LED Safety Statement LEDs have been tested and classified as “EXEMPT RISK GROUP” to the standard: IEC 62471:2006.
  • Page 7 Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation expo- sure. Patents For patent information, please refer to www.honeywellaidc.com/patents. Solids and Water Protection The Xenon 1900 has a rating of IP41, immunity of foreign particles and dripping water.
  • Page 8 Product Agency Compliance - Xenon 1902 and CCB01-010BT Base FCC Part 15 Subpart C This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference.
  • Page 9 5627 BT Eindhoven The Netherlands Honeywell shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. This equipment is intended for...
  • Page 10 Este produto está homologado pela ANATEL, de acordo com os procedi- mentos regulamentados pela Resolução No. 242/2000 e atende aos requi- sitos técnicos aplicados. Para maiores informações, consulte o site da ANATEL – www.anatel.gov.br Modelo: Xenon 1902 2876-10-6583 (01)07898927490072 " Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações...
  • Page 11 Conforms to NOM-019. Russia Taiwan If the following label is attached to your product, the product meets Taiwan agency approval: BSMI Standard: CNS13438, CNS14336 (Xenon 1902 only) 依據標準 : CNS13438, CNS14336 NCC standard: Low power frequency electric machineries technical standard: LP0002 International LED Safety Statement LEDs have been tested and classified as “EXEMPT RISK GROUP”...
  • Page 12 Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation expo- sure. Solids and Water Protection The Xenon 1902 has a rating of IP41, immunity of foreign particles and dripping water. Patents For patent information, please refer to www.honeywellaidc.com/patents.
  • Page 13 Required Safety Labels Scanner Illumination output Item Compliance Number, Serial Label Number and location Revision Information location...
  • Page 14 CCB01-010BT Base Item Number, Serial Number and Compliance Revision Label Information location location...
  • Page 15: Table Of Contents

    ® Verifone Ruby Terminal Default Settings .... 2-6 ® Gilbarco Terminal Default Settings ..... 2-7 Honeywell Bioptic Aux Port Configuration..... 2-7 © Datalogic™ Magellan Bioptic Aux Port Configuration............ 2-7 NCR Bioptic Aux Port Configuration...... 2-8 Wincor Nixdorf Terminal Default Settings ..... 2-8...
  • Page 16 Wincor Nixdorf Beetle™ Terminal Default Settings ..........2-9 Keyboard Country Layout ..........2-10 Keyboard Style ............2-17 Keyboard Conversion ..........2-18 Control Character Output...........2-19 Keyboard Modifiers............2-19 RS232 Baud Rate............2-22 RS232 Word Length: Data Bits, Stop Bits, and Parity ..............2-23 RS232 Receiver Time-Out.........2-24 RS232 Handshaking..........2-24 RS232 Timeout ............
  • Page 17 Charging Information..........3-5 Battery Recommendations ........3-5 Proper Disposal of the Battery ......3-6 Beeper and LED Sequences and Meaning ....3-6 Scanner LED Sequences and Meaning ....3-7 Base/Access Point LED Sequences and Meaning ............3-7 Base Power Communication Indicator ....3-8 Reset Scanner ............
  • Page 18 Scanner Name............3-22 Application Work Groups ...........3-24 Application Work Group Selection ....... 3-25 Resetting the Factory Defaults: All Application Work Groups........3-25 Resetting the Custom Defaults: All Application Work Groups........3-26 Using the Scanner with Bluetooth Devices....3-26 PCs/Laptops ............3-26 PDAs/Mobility Systems Devices ......3-27 Changing the Scanner’s Bluetooth PIN Code..
  • Page 19 Scanner Power Time-Out Timer......4-7 Presentation Mode ............4-9 Presentation LED Behavior after Decode ..... 4-9 Presentation Sensitivity ......... 4-9 Presentation Centering........4-10 In-Stand Sensor Mode ..........4-11 ® CodeGate ..............4-12 Streaming Presentation™ Mode ....... 4-12 Streaming Presentation In-Stand Programming ..........
  • Page 20 Working Orientation ...........4-27 Chapter 5 - Data Editing Prefix/Suffix Overview..........5-1 To Add a Prefix or Suffix: ........5-1 To Clear One or All Prefixes or Suffixes ....5-2 To Add a Carriage Return Suffix to All Symbologies..........5-3 Prefix Selections ............5-3 Suffix Selections ............5-4 Function Code Transmit ..........5-4 Intercharacter, Interfunction,...
  • Page 21 Codabar ..............7-3 Codabar Concatenation ........7-4 Code 39............... 7-6 Code 32 Pharmaceutical (PARAF)......7-8 Full ASCII .............. 7-9 Code 39 Code Page..........7-9 Interleaved 2 of 5 ............7-10 NEC 2 of 5..............7-12 Code 93..............7-14 Code 93 Code Page..........7-15 Straight 2 of 5 Industrial (three-bar start/stop) ..
  • Page 22 GS1 Composite Codes ..........7-45 UPC/EAN Version..........7-45 GS1 Emulation............7-46 TCIF Linked Code 39 (TLC39) ........7-47 QR Code..............7-47 QR Code Page ............ 7-48 Data Matrix ..............7-49 Data Matrix Code Page ........7-49 MaxiCode..............7-51 Aztec Code ..............7-52 Aztec Code Page ..........7-53 Chinese Sensible (Han Xin) Code ......7-54 Postal Codes - 2D............7-55 Single 2D Postal Codes: ........
  • Page 23 Chapter 10 - Utilities To Add a Test Code I.D. Prefix to All Symbologies ............10-1 Show Decoder Revision ..........10-1 Show Scan Driver Revision........10-1 Show Software Revision ........... 10-1 Show Data Format ............ 10-2 Test Menu ..............10-2 TotalFreedom ............
  • Page 24 Chapter 13 - Maintenance Repairs ..............13-1 Maintenance ..............13-1 Cleaning the Scanner .......... 13-1 Cleaning the Window ........... 13-1 Health Care Housing ........... 13-1 Inspecting Cords and Connectors ....... 13-2 Replacing Cables in Corded Scanners......13-2 Replacing an Interface Cable ......13-3 Replacing Cables and Batteries in Cordless Systems..........13-3 Replacing an Interface Cable in a Base ....
  • Page 25: Chapter 1 - Getting Started

    Xenon™ 1900 and 1902 area-imaging scanners. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
  • Page 26: Connecting The Device

    Connecting the Device Connecting with USB A scanner or a cordless base can be connected to the USB port of a com- puter. Connect the appropriate interface cable to the device first, then to the computer. Corded Scanner USB Connection: Cordless Base USB Connection: 1 - 2...
  • Page 27: Connecting With Keyboard Wedge

    Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. The scanner beeps. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual.
  • Page 28 Cordless Base Keyboard Wedge Connection: Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. Turn the terminal/computer power back on. The scanner beeps. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols...
  • Page 29: Connecting With Rs232 Serial Port

    Connecting with RS232 Serial Port Turn off power to the terminal/computer. Connect the appropriate interface cable to the scanner. Note: For the scanner or cordless base to work properly, you must have the correct cable for your type of terminal/computer. Corded Scanner RS232 Serial Port Connection:...
  • Page 30: Connecting With Rs485

    Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. Once the scanner or cordless base has been fully connected, power up the computer.
  • Page 31 Cordless Base RS485 Connection: Make sure the cables are secured in the wireways in the bottom of the cordless base and that the base sits flat on a horizontal surface. Turn the terminal/computer power back on. The scanner beeps. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual.
  • Page 32: Reading Techniques

    15° to 18° to prevent unwanted reflection. Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by send- ing serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings.
  • Page 33: Setting Custom Defaults

    Setting Custom Defaults You have the ability to create a set of menu commands as your own, custom defaults. To do so, scan the Set Custom Defaults bar code below before each menu command or sequence you want saved. If your command requires scan- ning numeric codes from the back cover, then a Save code, that entire sequence will be saved to your custom defaults.
  • Page 34: Resetting The Factory Defaults

    there are no custom defaults, it will reset the scanner to the factory default set- tings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings. Activate Custom Defaults Note: If using a cordless system, scanning this bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked.
  • Page 35: Chapter 2 - Programming The Interface

    Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
  • Page 36: Rs232 Serial Port

    RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface bar code also pro- grams a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated below.
  • Page 37: Rs485 Packet Mode

    Each bar code above also programs the following suffixes for each symbol- ogy: Symbology Suffix Symbology Suffix EAN 8 Code 39 00 0A 0B EAN 13 Interleaved 2 of 5 00 0D 0B UPC A Code 128 * 00 0A 0B UPC E Code 128 ** 00 18 0B...
  • Page 38: Usb Ibm Surepos

    USB IBM SurePos Scan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop scanner) interface. Note: After scanning one of these codes, you must power cycle the cash register.
  • Page 39: Usb Hid

    Scan the following code to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number.
  • Page 40: Verifone ® Ruby Terminal Default Settings

    ACK/NAK Mode ACK/NAK Mode On * ACK/NAK Mode Off ® Verifone Ruby Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Veri- fone Ruby terminal. This bar code sets the baud rate to 1200 bps and the data format to 8 data bits, no parity bit, 1 stop bit.
  • Page 41: Gilbarco ® Terminal Default Settings

    EAN-8 EAN-13 Gilbarco Settings Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honey- well bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit.
  • Page 42: Ncr Bioptic Aux Port Configuration

    NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration. The following prefixes are pro- grammed for each symbology: Symbology Prefix Symbology Prefix UPC-A Code 39 UPC-E Interleaved 2 of 5 EAN-8...
  • Page 43: Wincor Nixdorf Beetle™ Terminal Default Settings

    Wincor Nixdorf Beetle™ Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal. The following prefixes are programmed for each symbology: Symbology Prefix Symbology Prefix Code 128 EAN-13 Code 93 GS1-128 Codabar Interleaved 2 of 5...
  • Page 44: Keyboard Country Layout

    Keyboard Country Layout Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are sup- ported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘...
  • Page 45 Keyboard Country (continued) Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) 2 - 11...
  • Page 46 Keyboard Country (continued) Estonia Faeroese Finland France Gaelic Germany Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin) Greek (MS) 2 - 12...
  • Page 47 Keyboard Country (continued) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Irish Italian (142) Italy Japan ASCII Kazakh Kyrgyz (Cyrillic) Latin America Latvia 2 - 13...
  • Page 48 Keyboard Country (continued) Latvia (QWERTY) Lithuania Lithuania (IBM) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia 2 - 14...
  • Page 49 Keyboard Country (continued) Russian (MS) Russian (Typewriter) Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) 2 - 15...
  • Page 50 United States (Dvorak left) United States (Dvorak) United States (International) Uzbek (Cyrillic) Refer to the Honeywell website (www.honeywell.com/aidc) for complete key- board country support information and applicable interfaces. If you need to pro- gram a keyboard for a country other than one listed above, scan the Program...
  • Page 51: Keyboard Style

    appropriate country from the inside back cover, then the Save bar code. Program Keyboard Country Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Key- board Style settings.
  • Page 52: Keyboard Conversion

    Autocaps via NumLock bar code should be scanned in countries (e.g., Ger- many, France) where the Caps Lock key cannot be used to toggle Caps Lock. The NumLock option works similarly to the regular Autocaps, but uses the Num- Lock key to retrieve the current state of the Caps Lock. Autocaps via NumLock Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent).
  • Page 53: Control Character Output

    Control Character Output This selection sends a text string instead of a control character. For example, when the control character for a carriage return is expected, the output would display [CR] instead of the ASCII code of 0D. Refer to ASCII Conversion Chart (Code Page 1252) on page A-4.
  • Page 54 Default = Control + ASCII Mode Off. Windows Mode Control + ASCII Mode On * Control + ASCII Mode Off DOS Mode Control + ASCII Mode Windows Mode Prefix/Suffix Off Turbo Mode: The scanner sends characters to a terminal faster. If the termi- nal drops characters, do not use Turbo Mode.
  • Page 55 Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Automatic Direct Connect Mode * Automatic Direct Connect Mode Off 2 - 21...
  • Page 56: Rs232 Baud Rate

    RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as the scanner. Default = 9600. 1200 2400 4800 * 9600 19200 38400 57,600...
  • Page 57: Rs232 Word Length: Data Bits, Stop Bits, And Parity

    RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an applica- tion requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits.
  • Page 58: Rs232 Receiver Time-Out

    RS232 Receiver Time-Out The unit stays awake to receive data until the RS232 Receiver Time-Out expires. A manual or serial trigger resets the time-out. When an RS232 receiver is sleeping, a character may be sent to wake up the receiver and reset the time-out.
  • Page 59: Rs232 Timeout

    RS232 Timeout When using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the length (in millisec- onds) for a timeout by scanning the bar code below, then setting the time- out (from 1-5100 milliseconds) by scanning digits from the inside back cover, then scanning Save.
  • Page 60: Scanner To Bioptic Communication

    ACK/NAK On * ACK/NAK Off Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner. See...
  • Page 61: Scanner-Bioptic Ack/Nak Mode

    Scanner-Bioptic ACK/NAK Mode Bioptic ACK/Nak On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each packet is sent. The Scanner- Bioptic ACK/NAK Timeout (below) controls how long the scanner will wait for a response.
  • Page 62 2 - 28...
  • Page 63: Chapter 3 - Cordless System Operation

    Cordless System Operation Note: This chapter applies only to cordless scanning systems. It does not apply to corded scanners. How the Cordless Charge Base/Access Point Works A cordless charge base or an Access Point provide the link between the cord- less scanner and the host system.
  • Page 64: Linking The Scanner To An Access Point

    Linking the Scanner to an Access Point Turn on the computer (laptop/desktop). Plug the interface cable into the Access Point first and then Page into the appropriate port on the computer. The Button Page button lights up when the connection to the host is made.
  • Page 65: Rf (Radio Frequency) Module Operation

    been properly sent to the base or Access Point, the scanner issues an error indication. You must then check to see if the scanned data was received by the host system. RF (Radio Frequency) Module Operation The cordless system uses a two-way Bluetooth® radio to transmit and receive data between the scanner and the base or Access Point.
  • Page 66: Scanner Is Out Of Range

    Scanner Is Out of Range The cordless scanner is in communication with its base or Access Point, even when it is not transmitting bar code data. Whenever the scanner can’t communicate with the base or Access Point for a few seconds, it is out of range.
  • Page 67: Charging Information

    Replace it after the battery is unable to hold an adequate charge. • If you are not sure if the battery or charger is working properly, send it to Honeywell International Inc. or an authorized service center for inspection. Refer to Customer Support on page 14-1 for additional information.
  • Page 68: Proper Disposal Of The Battery

    Caution: Danger of explosion if batteries are incorrectly replaced. Dispose of used batteries according to the recycle program for batteries as directed by the governing agency for the country where the batteries are to be discarded. Proper Disposal of the Battery When the battery has reached the end of its useful life, the battery should be disposed of by a qualified recycler or hazardous materials handler.
  • Page 69: Scanner Led Sequences And Meaning

    Scanner LED Sequences and Meaning LED Indication Beeper Indication Cause Normal Operation Red Flash None Battery low Green Flash 1 beep Successful communication or linking Red, blinking Razz or error tone Failed communication Menu Operation Green Flash 2 beeps Successful menu change Red, blinking Razz or error tone Unsuccessful menu...
  • Page 70: Base Power Communication Indicator

    Base Power Communication Indicator To display the power indicator on a base or an Access Point, scan the Base Power Communication Indicator On bar code. To turn off the power indi- cator, scan the Off bar code. Default = On . * Base Power Communication Indicator On Base Power Communication...
  • Page 71: Paging

    Paging Paging Mode By default, the paging button on the base or Access Point pages the scan- ners associated with that base or Access Point. If you want the paging but- ton on your base or Access Point to be disabled, scan the Paging Mode Off bar code, below.
  • Page 72: Number Of Beeps - Base Error

    The base can be configured to beep at a particular pitch when an error occurs, such as transmission problems to a host system. The beeper pitch codes modify the pitch (frequency) of the error tone the base emits when there is an error. Default = Low. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz)
  • Page 73: Scanner Address

    Scanner Address Scan the bar code below to determine the address of the scanner you are using. Scanner Address Base or Access Point Address Scan the bar code below to determine the address of the base or Access Point you are using. Base Address Scanner Modes The Xenon is capable of working in single scanner mode, multiple scanner...
  • Page 74: Linked Modes

    If you want to charge a scanner and link to the base, use Charge and Link Mode. If the base is programmed for Charge Only Mode, you must link a scanner to it first in order to program it for Charge and Link Mode. Scan the linking bar code on the base to link the scanner, then scan Charge and Link Mode.
  • Page 75: Unlinking The Scanner

    bar code. Each time a scanner is placed into a base or scans an Access Point linking bar code, the scanner becomes the linked to the base or Access point and the old scanner is unlinked. * Open Link Mode (Single Scanner) Unlinking the Scanner If a base or an Access Point has a scanner linked to it, that scanner must be...
  • Page 76: Alarm Sound Type

    code below and then set the time-out duration (from 0-3000 seconds) by scan- ning digits on the Programming Chart inside the back cover, then scanning Save. Default = 0 sec (no alarm). Base Alarm Duration Note: The Access Point does not have a base alarm.
  • Page 77: Flexible Power Management

    Flexible Power Management If you are experiencing network performance issues, and suspect the scanner is interfering with other devices, you can turn down the power output of the scan- ner. This reduces the range between the scanner and a base or an Access Point as shown in the following illustration: 802.11 1902...
  • Page 78: Batch Mode

    Reset Scanner and Base/Access Point Once the power level is set, you must scan the Reset Base bar code and wait for the scanner to unlink and relink to a base or an Access Point. Once that is done, scan the Reset Scanner bar code and wait for the base or Access Point to unlink and relink to the scanner.
  • Page 79: Batch Mode Beep

    Default = Batch Mode Off. * Batch Mode Off Automatic Batch Mode Inventory Batch Mode Batch Mode Beep When using Batch Mode, scan Batch Mode Beep On to program the scan- ner to click when each bar code is read to storage. Default = Batch Mode Beep On.
  • Page 80: Batch Mode Quantity

    RAM Storage: The scanner will not power down while it contains data that has not been transmitted to the base or Access Point, even if it reaches a power down timeout. However, if the scanner runs out of battery power, it will power down and the data will be lost.
  • Page 81 2. Scan the quantity 1 bar code. 3. Scan the quantity 5 bar code. 4. Scan the quantity 0 bar code. 5. Scan the quantity 0 bar code. Example: Change a quantity of 103 to 10. To correct an incorrect quantity, scan the quantity 0 bar code to replace the incorrect digits, then scan the correct quantity bar codes.
  • Page 82: Batch Mode Output Order

    Quantity Codes (continued) Batch Mode Output Order When batch data is transmitted, select whether you want that data sent as FIFO (first-in first-out), or LIFO (last-in last-out). Batch Mode FIFO Batch Mode LIFO Delete Last Code If you want to delete the last bar code scanned when in Batch Mode, scan Delete Last Code.
  • Page 83: Transmit Records To Host

    Transmit Records to Host If you are operating in Inventory Batch Mode (see Inventory Batch Mode page 3-17), you must scan the following bar code to transmit all the stored data to the host system. Transmit Inventory Records Batch Mode Transmit Delay Sometimes when accumulated scans are sent to the host system, the transmission of those scans is too fast for the application to process.
  • Page 84: Scanner Name

    To put the scanner in multiple scanner mode, scan the bar code below. Once you scan this bar code, the scanner is unlinked from the base or Access Point and must either be placed into the base, or you must scan the Access Point link- ing bar code in order to relink.
  • Page 85 To rename scanners with sequential, numeric names, scan the bar codes below. Scan the Reset code after each name change and wait for the scanner to relink to the base or Access Point before scanning a bar code to rename the next scanner.
  • Page 86: Application Work Groups

    Conse- quently, any desired changes to either the retail or warehouse area would apply to all scanners in that particular work group. Honeywell’s online configuration tool, EZConfig...
  • Page 87: Application Work Group Selection

    Application Work Group Selection This programming selection allows you to assign a scanner to a work group by scanning the bar code below. You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires. Default = Group 0. * Group 0 Group 1 Group 2...
  • Page 88: Resetting The Custom Defaults: All Application Work Groups

    The scanner can be used either with the CCB01-010BT charge base, an Access Point, or with other Bluetooth devices. Those devices include personal computers, laptops, PDAs, and Honeywell mobility systems devices. PCs/Laptops Scanning the Non-Base BT Connection bar code below allows the scan- ner to be used with other Bluetooth devices (e.g., PC/laptop).
  • Page 89: Pdas/Mobility Systems Devices

    Non-Base BT Connection PDAs/Mobility Systems Devices You may also use the scanner with a PDA or a Honeywell Mobility Systems device. Scan the bar code below and follow the instructions supplied with your Bluetooth device to locate the scanner, and connect with it.
  • Page 90: Auto Reconnect Mode

    Auto Reconnect Mode Auto Reconnect controls whether or not the scanner automatically begins the relink process when a loss of connection is detected. When the Auto Reconnect On bar code is scanned, the scanner begins the relink process immediately, without user intervention. Default = Auto Reconnect On. * Auto Reconnect On Auto Reconnect Off Note: If you are connecting to a Bluetooth Interface Module, set Auto...
  • Page 91: Maximum Link Attempts

    Event Auto Reconnect On Auto Reconnect Off Scanner power Trigger must be pulled, Access Point linking bar down due to Power code must be scanned, or the scanner must be Time-Out Timer placed in the base unit to relink. setting (see page 4- (Note: scanner relinks on power up, but powers on due to one of the above actions.)
  • Page 92: Relink Time-Out

    Relink Time-Out Relink Time-Out controls the idle time between relink attempts. An attempt to link a scanner to a base or an Access Point typically lasts up to 5 sec- onds. This is the time when the scanner is actually attempting a contact . Relink Time-Out controls the amount of time, in seconds, that elapses between the end of one connection attempt and the start of the next.
  • Page 93: Host Command Acknowledgment

    Auto Reconnect Mode set to 1 Maximum Link Attempts set to 0 Relink Time-Out set to 10 Scanner Power Time-Out Timer set to 1800 Note: See Scanner Power Time-Out Timer on page 4-7. The scanner attempts to connect to the base or Access Point every 15 sec- onds, measured from one attempt start to the next attempt start.
  • Page 94 • Scanner operation is suspended until 1) a valid escape string is received from the host system (via the base or Access Point) or 2) the scanner times out. • Once condition 1 or 2 above has been met, the scanner is ready to scan again, and the process repeats.
  • Page 95 Command Action <ESC> 8 Razz or error tone to indicate a decode/communication to host was unsuccessful. 3 - 33...
  • Page 96 3 - 34...
  • Page 97: Chapter 4 - Input/Output Settings

    Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. If you are using a cordless system, the base can also be programmed to beep when it is powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner.
  • Page 98: Trigger Click

    Trigger Click To hear an audible click every time the scanner trigger is pressed, scan the Trigger Click On bar code below. Scan the Trigger Click Off code if you don’t wish to hear the click. (This feature has no effect on serial or automatic trigger- ing.) Default = Trigger Click Off.
  • Page 99: Beeper Volume - Good Read

    Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High. Medium * High Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scan- ner emits on a good read.
  • Page 100: Beeper Pitch - Error

    Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scan- ner emits when there is a bad read or error. Default = Razz. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz) Beeper Duration –...
  • Page 101: Number Of Beeps - Good Read

    Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read.
  • Page 102: Good Read Delay

    Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay). * No Delay Short Delay (500 ms) Medium Delay (1,000 ms) Long Delay (1,500 ms) User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
  • Page 103: Serial Trigger Mode

    slightly less range than Normal mode. Enhanced mode is best used when you require a very fast scan speed and don’t require a long working range. Default = Manual Trigger-Normal. * Manual Trigger - Normal Manual Trigger - Enhanced Serial Trigger Mode You can activate the scanner either by pressing the trigger, or using a serial trig- ger command (see Trigger Commands...
  • Page 104 If there are no trigger pulls during the timer interval, the scanner goes into power down mode. Whenever the trigger is enabled, the timer is reset. If the scanner is placed in the charge base cradle and the battery is in the process of being charged, the scanner will not go into power down mode.
  • Page 105: Presentation Mode

    Presentation Mode Presentation Mode uses ambient light to detect bar codes. The LEDs remain off until a bar code is presented to the scanner, then the LEDs turn on automat- ically to read the code. If the light level in the room is not high enough, Presen- tation Mode may not work properly.
  • Page 106: Presentation Centering

    Presentation Centering Use Presentation Centering to narrow the scanner’s field of view when it is in the stand to make sure the scanner reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, Presentation Centering will insure that only the desired codes are read.
  • Page 107: In-Stand Sensor Mode

    Scan Presentation Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Presentation Centering = 40% for Top and Left, 60% for Bottom and Right.
  • Page 108: Codegate

    You may program a Streaming Presentation Mode (Normal, Enhanced, or Mobile Phone) you wish to use for in-stand scanning, and a Manual Trigger mode (Normal, Enhanced, or Mobile Phone) you wish to use for out-of-stand scanning. To do this, you must first scan the preferred Streaming Presentation mode (see below), then scan the Manual Trigger mode (see page 4-6 page...
  • Page 109: Streaming Presentation In-Stand Programming

    You cannot take images when in Streaming Presentation Mode. To take images, scan Image Snap and Ship (see page 4-14). Note: If you are using a cordless charge base, it must have an external power supply plugged into the aux port for Streaming Presentation to work properly.
  • Page 110: Image Snap And Ship

    Image Snap and Ship Image Snap and Ship tells the scanner to take a picture (rather than read a bar code) when the trigger is pressed. Once the picture is snapped, it is shipped to the host system as a jpeg file by default. To revert to bar code reading, you must change to a different trigger mode (see Manual Trigger Modes beginning...
  • Page 111: User-Specified Reread Delay

    Use shorter delays in applications where repetitive bar code scanning is required. Reread Delay only works when in Presentation Mode (see page 4-9). Default = Medium. Short (500 ms) * Medium (750 ms) Long (1000 ms) Extra Long (2000 ms) User-Specified Reread Delay If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the...
  • Page 112: Aimer Delay

    Aimer Delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken. Use these codes to set the time between when the trigger is pulled and when the picture is taken. During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is over.
  • Page 113: Aimer Mode

    Aimer Mode This feature allows you to turn the aimer on and off. When the Interlaced bar code is scanned, the aimer is interlaced with the illumination LEDs. Default = Interlaced. * Interlaced Centering Use Centering to narrow the scanner’s field of view to make sure that when the scanner is hand-held, it reads only those bar codes intended by the user.
  • Page 114 In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read.
  • Page 115: Preferred Symbology

    Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual.
  • Page 116: High Priority Symbology

    Default = Scan a bar code below to enable or disable Preferred Symbology. Preferred Symbology Off. Preferred Symbology On * Preferred Symbology Off High Priority Symbology To specify the high priority symbology, scan the High Priority Symbology bar code below. On the Symbology Chart on page A-1, find the symbology you want to set as high priority.
  • Page 117: Preferred Symbology Default

    bar code has been encountered. Scan the bar code below, then set the delay (from 1-3,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 500 ms. Preferred Symbology Time-out Preferred Symbology Default Scan the bar code below to set all Preferred Symbology entries to their default values.
  • Page 118: To Add An Output Sequence

    To Add an Output Sequence 1. Scan the Enter Sequence symbol (see Require Output Sequence, page 4-25). 2. Code I.D. On the Symbology Chart on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover).
  • Page 119: Output Sequence Example

    Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. Note: Code 93 must be enabled to use this example. A - Code 39 B - Code 128 C - Code 93...
  • Page 120: Output Sequence Editor

    SEQBLKsequence editor start command code identifier for Code 39 0012 A - Code 39 sample length (11) plus CR suffix (1) = 12 start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 0013 B - Code 128 sample length (12) plus CR suffix (1) = 13 start character match for Code 128, 42h = “B”...
  • Page 121: Require Output Sequence

    Require Output Sequence When an output sequence is Required, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. When it’s On/Not Required, the scanner will attempt to get the output data to conform to an edited sequence but, if it cannot, the scanner transmits all output data to the host device as is.
  • Page 122: No Read

    No Read With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig Tool Scan Data Window (see page 10-3), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off.
  • Page 123: Working Orientation

    Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright. Upright: Vertical, Top to Bottom: (Rotate CW 90°)
  • Page 124 4 - 28...
  • Page 125: Chapter 5 - Data Editing

    Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
  • Page 126: To Clear One Or All Prefixes Or Suffixes

    symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4.
  • Page 127: To Add A Carriage Return Suffix To All Symbologies

    Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Chart, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix. Step 3.
  • Page 128: Suffix Selections

    Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page...
  • Page 129: Intercharacter Delay

    Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.
  • Page 130: Interfunction Delay

    Interfunction Delay An interfunction delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the num- ber of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this manual.
  • Page 131: Chapter 6 - Data Formatting

    Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For exam- ple, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
  • Page 132: Symbology Chart

    you are programming. (See Primary/Alternate Data Formats on page 6-11 for further information.) Step 3. Terminal Type Refer to Terminal ID Table (page 6-4) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits).
  • Page 133: Other Programming Selections

    Other Programming Selections Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the format you are clearing.
  • Page 134: Terminal Id Table

    Terminal ID Table Terminal Terminal Model(s) PC/AT and compatibles USB SurePOS Handheld Scanner USB SurePOS Tabletop Scanner RS232 True RS485 Serial PC Keyboard Mac Keyboard Japanese Keyboard (PC) HID POS Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character.
  • Page 135: Ascii Conversion Chart (Code Page 1252)

    A-4 for decimal, hex and character codes. Insert symbology name B3 Insert the name of the bar code’s symbology in the output message, without moving the cursor. Only symbologies with a Honeywell ID are included (see Symbology Chart on page A-1).
  • Page 136: Move Commands

    Key Modifiers Control Left Control Right For example, B501021F inserts an “A” on a 104 key, U.S. style keyboard. B5 = the command, 01 = number of keys pressed (without the key modifier), 02 is the key modifier for Shift Right, and 1F is the “a” key.
  • Page 137 Search backward for a character F9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F9xx where xx stands for the search character’s hex value for its ASCII code.
  • Page 138: Miscellaneous Commands

    Miscellaneous Commands Suppress characters FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy .
  • Page 139: Data Formatter

    Check for non-numeric character ED Check to make sure there is a non-numeric ASCII character at the current cursor position. The format is aborted if the character is numeric. Insert a delay EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position.
  • Page 140: Data Format Non-Match Error Tone

    Data Format Required, Keep Prefix/Suffix Scanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted.
  • Page 141: Primary/Alternate Data Formats

    will sound. If you wish to hear the error tone when a non-matching bar code is found, scan the Data Format Non-Match Error Tone On bar code. Default = Data Format Non-Match Error Tone On . * Data Format Non-Match Error Tone On Data Format Non-Match Error Tone Off...
  • Page 142 For example, you may have set your device to the data format you saved as Data Format 3. You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan-Data Format 1 bar code below. The next bar code that is scanned uses Data Format 1, then reverts back to Data For- mat 3.
  • Page 143 Symbologies This programming section contains the following menu selections. Refer to Chapter 11 for settings and defaults. • All Symbologies • Interleaved 2 of 5 • Aztec Code • Korea Post • China Post (Hong Kong 2 of 5) • Matrix 2 of 5 •...
  • Page 144: All Symbologies

    All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology.
  • Page 145: Codabar

    Codabar <Default All Codabar Settings> Codabar On/Off * On Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit . Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.”...
  • Page 146: Codabar Concatenation

    When Check Character is set to Validate, but Don’t Transmit , the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit...
  • Page 147: Codabar Message Length

    Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length 7 - 5...
  • Page 148: Code 39 Check Character

    Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
  • Page 149: Code 39 Message Length

    When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Charac- ter. * No Check Character Validate, but Don’t Transmit Validate and Transmit...
  • Page 150: Code 32 Pharmaceutical (Paraf)

    acter(s), it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger. The data is then transmitted in the order in which the bar codes were read (FIFO). Default = Off. * Off Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital-...
  • Page 151: Code Page Mapping Of Printed Bar Codes

    Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.
  • Page 152: Interleaved 2 Of 5

    and scan the value and the Save bar code from the Programming Chart the inside the back cover of this manual. The data characters should then appear properly. Code 39 Code Page Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Check Digit...
  • Page 153: Interleaved 2 Of 5 Message Length

    When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit...
  • Page 154: Nec 2 Of 5

    NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 155 NEC 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 7 - 13...
  • Page 156: Code 93

    Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
  • Page 157: Code 93 Code Page

    which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 93 bar code that starts with a character other than a space. Default = Off. * Off Code 93 Code Page Code pages define the mapping of character codes to characters.
  • Page 158: Straight 2 Of 5 Industrial (Three-Bar Start/Stop)

    Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Industrial Settings> Straight 2 of 5 Industrial On/Off * Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
  • Page 159: Straight 2 Of 5 Iata (Two-Bar Start/Stop)

    Straight 2 of 5 IATA (two-bar start/stop) <Default All Straight 2 of 5 IATA Settings> Straight 2 of 5 IATA On/Off * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
  • Page 160: Matrix 2 Of 5

    Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> Matrix 2 of 5 On/Off * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-80.
  • Page 161: Code 11

    Code 11 <Default All Code 11 Settings> Code 11 On/Off * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. One Check Digit * Two Check Digits 7 - 19...
  • Page 162: Code 128

    Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 <Default All Code 128 Settings>...
  • Page 163: Code 128 Message Length

    that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off. * Off Code 128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
  • Page 164: Code 128 Code Page

    Code 128 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
  • Page 165: Gs1-128

    GS1-128 <Default All GS1-128 Settings> GS1-128 On/Off * On GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80.
  • Page 166: Telepen

    Telepen <Default All Telepen Settings> Telepen On/Off * Off Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pat- tern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2).
  • Page 167: Upc-A

    Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Minimum Message Length Maximum Message Length UPC-A <Default All UPC-A Settings>...
  • Page 168 UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
  • Page 169: Upc-A/Ean-13

    UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code.
  • Page 170: Coupon Gs1 Databar Output

    Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data.
  • Page 171 UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. * Off UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator...
  • Page 172 UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On UPC-E0 Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it.
  • Page 173: Upc-E1

    UPC-E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use UPC-E0 (page 7-28). If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. UPC-E1 On * UPC-E1 Off EAN/JAN-13 <Default All EAN/JAN Settings>...
  • Page 174 EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar...
  • Page 175: Isbn Translate

    EAN/JAN-13 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code (page 7-27).
  • Page 176: Ean/Jan-8

    EAN/JAN-8 <Default All EAN/JAN-8 Settings> EAN/JAN-8 On/Off * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On 7 - 34...
  • Page 177 EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar...
  • Page 178: Msi

    <Default All MSI Settings> MSI On/Off * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check charac- ters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned...
  • Page 179: Msi Message Length

    When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character(s), but will not transmit the check character(s) with the scanned data. * Validate Type 10, but Don’t Transmit Validate Type 10 and Transmit Validate 2 Type 10 Characters,...
  • Page 180: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On 7 - 38...
  • Page 181: Gs1 Databar Expanded

    GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 4-74.
  • Page 182: Trioptic Code

    Trioptic Code Note: If you are going to scan Code 32 Pharmaceutical codes (page 7-8), Trioptic Code must be off. Trioptic Code is used for labeling magnetic storage media. * Off Codablock A <Default All Codablock A Settings> Codablock A On/Off * Off 7 - 40...
  • Page 183 Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. Minimum Message Length Maximum Message Length 7 - 41...
  • Page 184: Codablock F

    Codablock F <Default All Codablock F Settings> Codablock F On/Off * Off Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
  • Page 185: Pdf417

    PDF417 < Default All PDF417 Settings > PDF417 On/Off * On PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.
  • Page 186: Micropdf417

    MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On/Off * Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.
  • Page 187: Gs1 Composite Codes

    GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use. Default = Off. * Off UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite sym- bols that have a U.P.C.
  • Page 188: Gs1 Emulation

    GS1 Emulation The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any applica- tion that accepts GS1 data can be simplified since it only needs to recognize one data carrier type.) If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,...
  • Page 189: Tcif Linked Code 39 (Tlc39)

    TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected.
  • Page 190: Qr Code Page

    QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089. Minimum Message Length Maximum Message Length QR Code Page QR Code pages define the mapping of character codes to characters.
  • Page 191: Data Matrix

    Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116.
  • Page 192 page A-6), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Data Matrix Code Page Low Density Data Matrix If you are reading low density Data Matrix codes (codes with little informa- tion), you can scan the Low Density Codes On bar code below.
  • Page 193: Maxicode

    MaxiCode < Default All MaxiCode Settings > MaxiCode On/Off * Off MaxiCode Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150.
  • Page 194: Aztec Code

    Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832.
  • Page 195: Aztec Code Page

    ter(s), it buffers the number of Aztec bar codes determined by information encoded in those bar codes. Once the proper number of codes is reached, the data is output in the order specified in the bar codes. Default = Off. * Off Aztec Code Page Aztec Code pages define the mapping of character codes to characters.
  • Page 196: Chinese Sensible (Han Xin) Code

    Chinese Sensible (Han Xin) Code < Default All Han Xin Settings > Han Xin Code On/Off * Off Han Xin Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Mini- mum and Maximum lengths = 1-7833.
  • Page 197: Postal Codes - 2D

    Postal Codes - 2D The following lists the possible 2D postal codes, and 2D postal code combina- tions that are allowed. Only one 2D postal code selection can be active at a time. If you scan a second 2D postal code selection, the first selection is over- written.
  • Page 198: Combination 2D Postal Codes

    Postnet On Also see Postnet Check Digit, page 7-58. Postnet with B and B’ Fields On InfoMail On Combination 2D Postal Codes: InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B’ Fields On Postnet and Postal-4i On Postnet and Intelligent Mail Bar Code On...
  • Page 199 Planet Code and Postal-4i On Planet Code and Intelligent Mail Bar Code On Planet Code, Postnet, and Postal-4i On Planet Code, Postnet, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Intelligent Mail Bar Code On Postnet, Postal-4i, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and...
  • Page 200 Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data.
  • Page 201: Postal Codes - Linear

    * Bar Output Numeric N Table Alphanumeric C Table Combination C and N Tables Postal Codes - Linear The following lists linear postal codes. Any combination of linear postal code selections can be active at a time. China Post (Hong Kong 2 of 5) <Default All China Post (Hong Kong 2 of 5) Settings>...
  • Page 202 China Post (Hong Kong 2 of 5) On/Off * Off China Post (Hong Kong 2 of 5) Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maxi- mum Default = 80.
  • Page 203: Korea Post

    Korea Post <Default All Korea Post Settings> Korea Post * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maxi- mum Default = 48.
  • Page 204 7 - 62...
  • Page 205: Chapter 8 - Imaging Commands

    Imaging Commands The scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands allow you to alter the way the scan- ner performs these functions. Note: If you are using the scanner in a stand, you must set the In-Stand Sensor Mode to Off in order to take images (see In-Stand Sensor Mode on page...
  • Page 206: Image Snap - Imgsnp

    Step 1 - Take a Picture Using IMGSNP Image Snap - IMGSNP An image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP) command is processed. The image snap command has many different modifiers that can be used to change the look of the image in memory.
  • Page 207 E - Exposure Exposure is used in Manual Style only (2P), and allows you to set the expo- sure time. This is similar to setting a shutter speed on a camera. The exposure time determines how long the scanner takes to record an image. On a bright day, exposure times can be very short because plenty of light is available to help record an image.
  • Page 208 W - Target White Value Sets the target for the median grayscale value in the captured image. For capturing close-up images of high contrast documents, a lower setting, such as 75, is recommended. Higher settings result in longer exposure times and brighter images, but if the setting is too high, the image may be overexposed.
  • Page 209: Image Ship - Imgshp

    Step 2 - Ship a Picture Using IMGSHP Image Ship - IMGSHP An image is taken whenever the button is pressed, or when the Image Snap (IMGSNP) command is processed. The last image is always stored in memory. You can “ship” the image by using the IMGSHP command. The image ship commands have many different modifiers that can be used to change the look of the image output.
  • Page 210 C - Compensation Flattens the image to account for variations in illumination across the image. 0C Compensation disabled (default) 1C Compensation enabled Example of Compensation at 0C: Example of Compensation at 1C: D - Pixel Depth Indicates the number of bits per pixel in the transmitted image (KIM or BMP format only).
  • Page 211 E - Edge Sharpen An edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper. While edge sharpening does make the image look cleaner, it also removes some fine detail from the original image. The strength of the edge sharpen filter can be entered from 1 to 24.
  • Page 212 H - Histogram Stretch Increases the contrast of the transmitted image. Not available with some image formats. 0H No stretch (default) 1H Histogram stretch Example of Histogram Stretch at 0H: Example of Histogram Stretch at 1H: I - Invert Image Invert image is used to rotate the image around the X or Y axis.
  • Page 213 IF- Noise Reduction Used to reduce the salt and pepper noise in an image. 0if No salt and pepper noise reduction (default) 1if Salt and pepper noise reduction Example of Noise Reduction Off (0if): Example of Noise Reduction On (1if): IR - Image Rotate 0ir Image as snapped (rightside up) (default) 1ir Rotate image 90 degrees to the right...
  • Page 214 J - JPEG Image Quality Sets the desired quality when the JPEG image format is selected. Higher numbers result in higher quality, but larger files. Smaller numbers result in greater amounts of lossy compression, faster transmission times, lower quality, but smaller files. (Default = 50) Image is compressed as much as possible while preserving quality factor of n ( n = 0 - 100) worst quality (smallest file)
  • Page 215 n B The bottom edge of the shipped image corresponds to row n - 1 of the image in memory. Range: 000 - 480. (Default = all rows) Uncropped Image: Example of Image Crop Example of Image set to 300R: Crop set to 300L: Example of Image Crop set to 200B: Example of Image Crop set to 200T:...
  • Page 216 1S ship every pixel (default) 2S ship every 2nd pixel, both horizontally and vertically 3S ship every 3rd pixel, both horizontally and vertically Example of Pixel Example of Pixel Example of Pixel Ship set to 1S: Ship set to 2S: Ship set to 3S: U - Document Image Filter Allows you to input parameters to sharpen the edges and smooth the area...
  • Page 217 V - Blur Image Smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image. 0V Don’t blur (default) 1V Blur Example of Blur Image Off (0V): Example of Blur Image On (1V): W - Histogram Ship A histogram gives a quick picture of the tonal range of an image, or key type.
  • Page 218: Intelligent Signature Capture - Imgbox

    Image Size Compatibility If you have applications that expect an image ship to return exactly 640x480 pixels, scan the Force VGA Resolution bar code. Default = Native Resolution Force VGA Resolution * Native Resolution Intelligent Signature Capture - IMGBOX IMGBOX allows you to configure the size and location of a signature capture area relative to its proximity to a bar code.
  • Page 219: Imgbox Modifiers

    The following IMGBOX example was executed and viewed using QuickView software. This software is available at www.honeywellaidc.com. Click on Soft- ware Downloads. Select 4600r from the Products list, then select QuickView Software Utility. Below is an example of a signature capture application. In this example, the aimer is centered over the signature capture area and the trigger is pressed.
  • Page 220 This option is used to size the image horizontally. If using this option, set the resolution (R) to zero. Example of Image Width set to 200A: Example of Image Width set to 600A: B - Output Image Height This option is used to size the image vertically. If using this option, set the resolution (R) to zero.
  • Page 221 8F BMP format H - Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by .01. In the example, the height of the area to be captured is 3/8 inch, resulting in a value of H = .375/0.01 = 37.5. Example: IMGBOX245w37h55y.
  • Page 222 For example, use 2500 to specify a resolution of 2.5. Set to zero when using the A and B modifiers (see A - Output Image Width B - Output Image Height on page 8-16). Example of Resolution set to 0R: Example of Resolution set to 1000R: Example of Resolution set to 2000R: S - Bar Code Aspect Ratio...
  • Page 223: Rf Default Imaging Device

    Y - Vertical Bar Code Offset The vertical bar code offset allows you to offset the vertical center of the signature capture area. Negative numbers indicate that the signature cap- ture is above the bar code, and positive numbers indicate that the area is below the bar code.
  • Page 224 8 - 20...
  • Page 225: Chapter 9 - Interface Keys

    Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-19 enable Control + ASCII mode. Function Code HEX/ASCII Value Full ASCII “CTRL”...
  • Page 226 The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes United States Belgium < Scandinavia <...
  • Page 227: Supported Interface Keys

    Supported Interface Keys IBM AT/XT and IBM XTs and IBM, DDC, PS/2 Compatibles Memorex Telex, ASCII Compatibles, Supported Harris* WYSE PC/AT Keys Supported Keys Supported Keys Reserved Reserved Reserved Enter (KP) CR/Enter Enter Cap Lock Caps Lock ALT make Reserved ALT break Reserved CTRL make...
  • Page 228 IBM AT/XT and IBM XTs and IBM, DDC, PS/2 Compatibles Memorex Telex, ASCII Compatibles, Supported Harris* WYSE PC/AT Keys Supported Keys Supported Keys * IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models) 9 - 4...
  • Page 229 Supported Interface Keys IBM, Memorex Telex Memorex Telex (88)** (102)* ASCII Supported Keys Supported Keys Reserved Reserved Enter Enter PF10 PF11 PF12 Reserved Reserved New Line New Line Field Forward Field Forward Reserved Tab/Field Forward Field Forward Delete Delete Field Exit New Line Insert Insert...
  • Page 230 Supported Interface Keys Esprit 200, 400 Esprit 200, 400 Esprit 200, 400 ANSI ASCII ASCII Supported Supported Supported Keys Keys Keys Reserved Reserved Reserved New Line New Line New Line New Line New Line New Line Delete New Line New Line New Line Insert Escape...
  • Page 231 Supported Interface Keys Apple Mac/iMac ASCII Supported Keys Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make APPLE break RETURN Ins Help Home Prnt Scrn BACKSPACE LSHIFT TAB BACKSPACE 9 - 7...
  • Page 232 9 - 8...
  • Page 233: Chapter 10 - Utilities

    Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
  • Page 234: Show Data Format

    Show Data Format Scan the bar code below to show current data format settings. DFMBK3?. Data Format Settings Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a programming code. The pro- gramming function will still occur, but in addition, the content of that program- ming code is output to the terminal.
  • Page 235: Application Plug-Ins (Apps)

    Application Plug-Ins (Apps) Any apps that you are using can be turned off or on by scanning the following bar codes. Apps are stored in groups: Decoding, and Formatting. You can enable and disable these groups of apps by scanning that group’s On or Off bar code below.
  • Page 236: Installing Ezconfig From The Web

    Note: EZConfig requires .NET software. If .NET is not installed on your PC, you will be prompted to install it during the EZConfig installation. 1. Access the Honeywell web site at www.honeywellaidc.com 2. Click on the Resources tab. Select Software.
  • Page 237 9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig. 10 - 5...
  • Page 238 10 - 6...
  • Page 239: Chapter 11 - Serial Programming Commands

    Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will pro- gram the scanner. For complete descriptions and examples of each serial pro- gramming command, refer to the corresponding programming bar code in this manual.
  • Page 240: Query Commands

    Storage A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table.
  • Page 241: Responses

    Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters.
  • Page 242: Trigger Commands

    MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled;...
  • Page 243: Menu Commands

    Menu Commands Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Product Default Settings Setting Custom Set Custom Defaults MNUCDF Defaults Save Custom DEFALT Defaults Resetting the Activate Custom DEFALT 1-10 Custom Defaults Defaults Resetting the Factory Remove Custom DEFOVR 1-10...
  • Page 244 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Plug and Play Codes: IBM Port 5B PAPP5B RS485 Interface IBM Port 9B PAP9B1 HHBCR-1 Interface IBM Port 17 PAPP17 Interface IBM Port 9B PAP9B2 HHBCR-2 Interface RS485 Packet Mode RTLPDF1 RS485 Packet Mode...
  • Page 245 Selection Page # Indicates a numeric * Indicates default entry Plug and Play Codes Verifone Ruby PAPRBY Terminal Gilbarco Terminal PAPGLB Honeywell Bioptic PAPBIO Aux Port Datalogic Magellan PAPMAG Bioptic Aux Port NCR Bioptic Aux PAPNCR Port Wincor Nixdorf PAPWNX...
  • Page 246 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Program Keyboard Czech KBDCTY40 2-11 Country (Programmers) Czech (QWERTY) KBDCTY39 2-11 Czech (QWERTZ) KBDCTY38 2-11 Denmark KBDCTY8 2-11 Dutch (Netherlands) KBDCTY11 2-11 Estonia KBDCTY41 2-12 Faeroese KBDCTY83 2-12 Finland KBDCTY2...
  • Page 247 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Program Keyboard Latvia (QWERTY) KBDCTY43 2-14 Country Lithuania KBDCTY44 2-14 Lithuania (IBM) KBDCTY45 2-14 Macedonia KBDCTY34 2-14 Malta KBDCTY74 2-14 Mongolian (Cyrillic) KBDCTY86 2-14 Norway KBDCTY9 2-14 Poland KBDCTY20 2-14...
  • Page 248 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Program Keyboard Ukrainian KBDCTY76 2-16 Country United Kingdom KBDCTY7 2-16 United Stated KBDCTY89 2-16 (Dvorak right) United States KBDCTY88 2-16 (Dvorak left) United States KBDCTY87 2-16 (Dvorak) United States KBDCTY30 2-16...
  • Page 249 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Keyboard Modifiers *Control + ASCII Off KBDCAS0 2-20 DOS Mode Control KBDCAS1 2-20 + ASCII Windows Mode KBDCAS2 2-20 Control + ASCII Windows Mode KBDCAS3 2-20 Prefix/Suffix Off *Turbo Mode Off KBDTMD0 2-20...
  • Page 250 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry 2-23 Word Length: Data 7 Data, 1 Stop, 232WRD3 Bits, Stop Bits, and Parity Even Parity 7 Data, 1 Stop, 232WRD0 2-23 Parity None 7 Data, 1 Stop, 232WRD6 2-23 Parity Odd...
  • Page 251 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Scanner-Bioptic *Bioptic ACK/NAK 232NAK0 2-27 ACK/NAK Mode Bioptic ACK/NAK 232NAK1 2-27 Scanner-Bioptic ACK/NAK Timeout 232DLK##### 2-27 ACK/NAK Timeout *5100 Cordless System Operation Note: This section applies only to cordless systems. It does not apply to corded scanners.
  • Page 252 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Scanner Modes Charge Only Mode BASLNK0 3-11 *Charge and Link BASLNK1 3-12 Mode Locked Link Mode BASCON0,DNG1 3-13 *Open Link Mode BASCON1,DNG1 3-13 Unlink Scanner BT_RMV 3-13 Override Locked BT_RPL1 3-13...
  • Page 253 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Quantity Codes BATNUM0 3-19 BATNUM1 3-19 BATNUM2 3-19 BATNUM3 3-19 BATNUM4 3-19 BATNUM5 3-19 BATNUM6 3-19 BATNUM7 3-19 BATNUM8 3-20 BATNUM9 3-20 Batch Mode Output FIFO BATLIF0 3-20 Order LIFO...
  • Page 254 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Resetting the Custom Default PAPDFT 3-26 Custom Defaults: All Settings: Application Work All Work Groups Groups Bluetooth PCs/Laptops: BT_DNG5 3-27 Connection Non-Base BT Connection BT Connection - BT_DNG1 3-27 PDA/Mobility...
  • Page 255 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Beeper Volume - BEPLVL0 Good Read BEPLVL1 Medium BEPLVL2 *High BEPLVL3 Beeper Pitch - Good Low (1600) (min BEPFQ11600 Read (Frequency) 400Hz) *Medium 2700) BEPFQ12700 High (4200) (max BEPFQ14200 9000Hz) Beeper Pitch - Error...
  • Page 256 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Manual Trigger *Manual Trigger - PAPHHF Modes Normal Manual Trigger - PAPHHS Enhanced Serial Trigger Mode Read Time-Out TRGSTO#### (0 - 300,000 ms) *30,000 Scanner Power BT_LPT0 Time-Out Timer (0- BT_LPT200 7200 seconds)
  • Page 257 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Presentation Presentation PDCWIN1 4-11 Centering Window Centering On *Presentation PDCWIN0 4-11 Centering Off Left of Presentation PDCLFT### 4-11 Centering Window (*40%) Right of PDCRGT### 4-11 Presentation Centering Window (*60%) Top of Presentation PDCTOP###...
  • Page 258 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Image Snap and Image Snap and TRGMOD6 4-14 Ship Ship Hands Free Time- Range 0 - 300,000 TRGPTO###### 4-14 Reread Delay Short (500 ms) DLYRRD500 4-15 *Medium (750 ms) DLYRRD750 4-15 Long (1000 ms)
  • Page 259 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Preferred Symbology PRFENA1 4-20 *Off PRFENA0 4-20 High Priority PRFCOD## 4-20 Symbology Low Priority PRFBLK## 4-20 Symbology Preferred PRFPTO#### 4-21 Symbology Timeout (*500) Range 100- 3000 Preferred PRFDFT 4-21 Symbology Default...
  • Page 260 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Working Orientation *Upright ROTATN0 4-27 Vertical, Bottom to ROTATN1 4-27 Top (Rotate CCW 90°) Upside Down ROTATN2 4-27 Vertical, Top to ROTATN3 4-27 Bottom (Rotate CW 90°) Prefix/Suffix Selections Add CR Suffix to All Symbologies VSUFCR...
  • Page 261 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Data Formatter Selections Data Format Editor *Default Data DFMDF3 Format (None) Enter Data Format DFMBK3## Clear One Data DFMCL3 Format Clear All Data DFMCA3 Formats Data Formatter Data Formatter Off DFM_EN0 *Data Formatter On,...
  • Page 262 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Single Scan Data Single Scan-Primary VSAF_0 6-12 Format Change Data Format Single Scan-Data VSAF_1 6-12 Format 1 Single Scan-Data VSAF_2 6-12 Format 2 Single Scan-Data VSAF_3 6-12 Format 3 Symbologies All Symbologies...
  • Page 263 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Code 39 Start/Stop *Don’t Transmit C39SSX0 Char. Transmit C39SSX1 Code 39 Check Char. *No Check Char. C39CK20 Validate, But Don’t C39CK21 Transmit Validate, C39CK22 and Transmit Code 39 Message Minimum (0 - 48) *0 C39MIN## Length...
  • Page 264 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry NEC 2 of 5 Default All NEC N25DFT 7-12 2 of 5 Settings N25ENA0 7-12 N25ENA1 7-12 NEC 2 of 5 Check *No Check Char. N25CK20 7-12 Digit Validate, But Don’t N25CK21...
  • Page 265 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Straight 2 of 5 IATA *Off A25ENA0 7-17 A25ENA1 7-17 Straight 2 of 5 IATA Minimum (1 - 48) *4 A25MIN## 7-17 Message Length Maximum (1 - 48) A25MAX## 7-17 Matrix 2 of 5...
  • Page 266 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Code 128 Code Page Code 128 Code 128DCP## 7-22 Page (*2) GS1-128 Default All GS1-128 GS1DFT 7-23 Settings GS1ENA1 7-23 GS1ENA0 7-23 GS1-128 Message Minimum (1 - 80) *1 GS1MIN 7-23 Length...
  • Page 267 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry UPC-A Addenda UPAADS0 7-27 Separator UPAADS1 7-27 UPC-A/EAN-13 with *Off CPNENA0 7-27 Extended Coupon Allow Concatenation CPNENA1 7-27 Code Require CPNENA2 7-27 Concatenation Coupon GS1 GS1 Output Off CPNGS10 7-28 DataBar Output...
  • Page 268 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry EAN/JAN-13 Check E13CKX0 7-31 Digit E13CKX1 7-31 EAN/JAN-13 2 Digit 2 Digit Addenda On E13AD21 7-32 Addenda *2 Digit Addenda Off E13AD20 7-32 5 Digit Addenda On E13AD51 7-32 *5 Digit Addenda Off...
  • Page 269 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry MSI Check Character *Validate Type 10, MSICHK0 7-37 but Don’t Transmit Validate Type 10 and MSICHK1 7-37 Transmit Validate 2 Type 10 MSICHK2 7-37 Chars, but Don’t Transmit Validate 2 Type 10 MSICHK3...
  • Page 270 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry GS1 DataBar Default All GS1 RSEDFT 7-39 Expanded DataBar Expanded Settings RSEENA0 7-39 RSEENA1 7-39 GS1 DataBar Minimum (4 - 74) *4 RSEMIN## 7-39 Expanded Msg. Maximum (4 - 74) RSEMAX## 7-39 Length...
  • Page 271 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry PDF417 Msg. Length Minimum (1-2750) PDFMIN 7-43 Maximum (1-2750) PDFMAX 7-43 *2750 MicroPDF417 Default All Micro MPDDFT 7-44 PDF417 Settings MPDENA1 7-44 *Off MPDENA0 7-44 MicroPDF417 Msg. Minimum (1-366) *1 MPDMIN 7-44...
  • Page 272 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry QR Code Msg. Minimum (1-7089) QRCMIN 7-48 Length Maximum (1-7089) QRCMAX 7-48 *7089 QR Code Page QR Code Page (*3) QRCDCP## 7-48 Data Matrix Default All Data IDMDFT 7-49 Matrix Settings...
  • Page 273 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Aztec Append AZTAPP1 7-53 *Off AZTAPP0 7-53 Aztec Code Page Aztec Code Page AZTDCP## 7-53 (*51) Chinese Sensible Default All Han Xin HX_DFT 7-54 (Han Xin) Code Code Settings HX_ENA1 7-54...
  • Page 274 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Combination 2D InfoMail and British POSTAL8 7-56 Postal Codes Post On Intelligent Mail Bar POSTAL20 7-56 Code and Postnet with B and B’ Fields Postnet and Postal- POSTAL14 7-56 4i On...
  • Page 275 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Combination 2D Postnet, Postal-4i, POSTAL24 7-57 Postal Codes and Intelligent Mail (continued) Bar Code On Planet, Postal-4i, POSTAL25 7-57 and Postnet with B and B’ Fields On Planet, Intelligent POSTAL26 7-57...
  • Page 276 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry China Post (Hong Default All China CPCDFT 7-59 Kong 2 of 5) Post (Hong Kong 2 of 5) Settings *Off CPCENA0 7-60 CPCENA1 7-60 China Post (Hong Minimum (2 - 80) *4 CPCMIN## 7-60...
  • Page 277 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Imaging Default Commands Image Snap Default all Imaging IMGDFT Commands Imaging Style - SNPSTY0 Decoding *Imaging Style - SNPSTY1 Photo Imaging Style - SNPSTY2 Manual Beeper On SNPBEP1 *Beeper Off SNPBEP0...
  • Page 278 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Image Ship *Infinity Filter - Off IMGINF0 Infinity Filter - On IMGINF1 *Compensation Off IMGCOR0 Compensation On IMGCOR1 *Pixel Depth - 8 bits/ IMGBPP8 pixel (grayscale) Pixel Depth - 1 bit/ IMGBPP1 pixel (B&W) *Don’t Sharpen...
  • Page 279 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Image Ship Invert Image around IMGNVX1 (continued) X axis Invert Image around IMGNVY1 Y axis Rotate Image none IMGROT0 Rotate Image 90° IMGROT1 right Rotate Image 180° IMGROT2 right Rotate Image 90°...
  • Page 280 Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Image Ship Ship Every 2nd Pixel IMGSUB2 8-12 (continued) Ship Every 3rd Pixel IMGSUB3 8-12 *Document Image IMGUSH0 8-12 Filter Off Document Image IMGUSH### 8-12 Filter On (0-255) *Don’t Ship IMGHST0 8-13...
  • Page 281: Scanner Product Specifications

    Product Specifications 1900 Scanner Product Specifications Parameter Specification Dimensions (Typical): Height 6.3 inches (16cm) Length 4.1 inches (10.41cm) Width 2.8 inches (7.11cm) Weight 5.2 ounces (147.42g) Illumination: Scan and Aiming LEDs 617nm + 18nm LED output power .339mW Image Size 838 x 640 pixels Skew Angle +65°...
  • Page 282: Scanner Product Specifications

    1902 Scanner Product Specifications Parameter Specification Dimensions (Typical): Height 6.3 inches (16 cm) Length 4.1 inches (10.41cm) Width 2.8 inches (7.11cm) Weight 7.5 ounces (212.62g) Illumination: Scan and Aiming LEDs 617nm + 18nm LED output power .339mW Image Size 838 x 640 pixels Skew Angle +65°...
  • Page 283: Ccb01-010Bt Charge Base Product Specifications

    CCB01-010BT Charge Base Product Specifications Parameter Specification Dimensions (Typical): Height 3.2 inches (8.128cm) Length 5.19 inches (13.183cm) Width 3.98 inches (10.109cm) Weight 6.3 oz (179g) Voltage: 4.5 to 5.5 volts Current Draw: Host Terminal Port 500mA Aux Power Port Charge Time 5 hours Radio: 2.4 to 2.5 GHz (ISM Band) Frequency Hopping...
  • Page 284: Ccb01-010Bt Charge Base Mounting

    CCB01-010BT Charge Base Mounting 2.36 in. 2.8 in. 59.84mm 72.1mm 3.35 in. 8x32 thread 85.09mm x .39 in. (10mm) deep 12 - 4...
  • Page 285: Standard Cable Pinouts

    Standard Cable Pinouts Keyboard Wedge 12 - 5...
  • Page 286: Serial Output

    Standard Cable Pinouts Serial Output 12 - 6...
  • Page 287: Rs485 Output

    Standard Cable Pinouts RS485 Output 12 - 7...
  • Page 288 Standard Cable Pinouts 12 - 8...
  • Page 289: Repairs

    Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These ser- vices are to be performed only by an authorized service center (see Customer Support on page 14-1). Maintenance Your device provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation: Cleaning the Scanner...
  • Page 290: Inspecting Cords And Connectors

    The interface cable is designed to be field replace- able. • Order replacement cables from Honeywell or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable.
  • Page 291: Replacing An Interface Cable

    Replacing an Interface Cable 1. Turn the power to the host system OFF. 2. Disconnect the scanner’s cable from the terminal or computer. 3. Locate the small hole on the back of the scanner’s handle. This is the cable release. 4.
  • Page 292: Changing A Scanner Battery

    Changing a scanner Battery 1. Loosen the thumb wheel screw on the end cap by hand or use a hex wrench. 2. Remove the battery from the handle. 3. Insert replacement battery. 4. Replace end cap and screw. End Cap Troubleshooting a Xenon Scanner The scanner automatically performs self-tests whenever you turn it on.
  • Page 293: Troubleshooting A Cordless System

    • The scanner may not be programmed for the appropriate terminal interface. For example, you scan “12345” and the host displays “@es%.” Reprogram the scanner with the correct Plug and Play bar code. See Programming the Interface beginning on page 2-1. •...
  • Page 294: Troubleshooting A Cordless Scanner

    Troubleshooting a Cordless Scanner Note: Make sure that your scanner’s battery is charged. Visit the Services and Support section of our website (www.honeywellaidc.com) to check for the latest software for both the scanner and the base or Access Point. Is the scanner having trouble reading your symbols? If the scanner isn’t reading symbols well, check that the symbols: •...
  • Page 295: Customer Support

    E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) E-mail: soporte.hsm@honeywell.com Europe, Middle East, and Africa Telephone: +31 (0) 40 7999 393 Fax: +31 (0) 40 2425 672 E-mail: hsmeurosupport@honeywell.com Hong Kong...
  • Page 296: Online Technical Assistance

    You can also access technical assistance online at www.honeywellaidc.com. Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.
  • Page 297: Online Product Service And Repair Assistance

    You can also access product service and repair assistance online at www.honeywellaidc.com. Limited Warranty Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used;...
  • Page 298 The duration of the limited warranty for the Xenon 1900 scanner is five (5) years. The duration of the limited warranty for the Xenon 1902 scanner and CCB01- 010BT Charge Base is three (3) years. The duration of the limited warranty for the Xenon battery is one (1) year.
  • Page 299: Symbology Chart

    Reference Charts Symbology Chart Possible AIM ID Code ID Symbology AIM ID Modifiers (hex) ( m ) All Symbologies (0x99) Australian Post A (0x41) ]z m Aztec Code 0-9, A-C z (0x7A) British Post B (0x42) Canadian Post C (0x43) China Post Q (0x51) Chinese Sensible Code (Han Xin...
  • Page 300 Possible AIM ID Code ID Symbology AIM ID Modifiers (hex) ( m ) GS1 Composite ]e m y (0x79) GS1 DataBar ]e m y (0x79) GS1 DataBar Limited ]e m { (0x7B) GS1 DataBar Omnidirectional ]e m y (0x79) GS1 DataBar Expanded ]e m } (0x7D) InfoMail...
  • Page 301 Possible AIM ID Code ID Symbology AIM ID Modifiers (hex) ( m ) Telepen ]B m t (0x54) UPC-A c (0x63) UPC-A with Add-On c (0x63) UPC-A with Extended c (0x63) Coupon Code UPC-E E (0x45) UPC-E with Add-On E (0x45) UPC-E1 E (0x45) Note: “m”...
  • Page 302 ASCII Conversion Chart (Code Page 1252 Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Non-Printable Characters DEC HEX Character (Code) DEC HEX Character (Code) NULL DATA LINK ESCAPE (DLE) START OF HEADING DEVICE CONTROL 1 (DC1) (SOH)
  • Page 303 Printable Characters (Continued) DEC HEX Character DEC HEX Character DEC HEX Character < > <DEL> Extended ASCII Characters DEC HEX Character DEC HEX Character DEC HEX Character € € « Ö ¬ × ‚ Ø ƒ ® Ù „ ¯ Ú...
  • Page 304: Code Page Mapping Of Printed Bar Codes

    Extended ASCII Characters (Continued) DEC HEX Character DEC HEX Character DEC HEX Character Œ · â ¸ ã Ž ¹ ä º å » æ ‘ ¼ ç ’ ½ è “ ¾ é ” ¿ ê • À ë –...
  • Page 305 one the host program is expecting. If this is the case, select the code page with which the bar codes were created. The data characters should then appear properly. Code Page Standard Description CP ISO646 2 (Default) ISO 2022 Automatic National Replacement Characters CP Binary ISO 8859 1 51...
  • Page 306: Unicode Key Maps

    Unicode Key Maps 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 4B 50 55 5A 5F 64 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 4C 51 56 5B 60 65 1F 20 21 22 23 24 25 26 27 28 29...
  • Page 307 Sample Symbols UPC-A Interleaved 2 of 5 0 123456 7890 Code 128 1234567890 EAN-13 Code 128 Code 39 9 780330 290951 Codabar BC321 Code 93 A13579B Straight 2 of 5 Industrial 123456-9$ 123456...
  • Page 308 Sample Symbols Matrix 2 of 5 GS1 DataBar 6543210 PDF417 (01)00123456789012 Car Registration Postnet Zip Code Data Matrix QR Code Test Symbol Numbers 4-CB (4-State Customer Bar Code) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T...
  • Page 309 Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message Test Message...
  • Page 310: Programming Chart

    Programming Chart...
  • Page 311 Programming Chart Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
  • Page 312 Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 Xenon-UG Rev C 3/11...

This manual is also suitable for:

Xenon 1900