8.3

Selecting Run Mode

(1) Function
Changes over the run mode of automatic operation.
(2) Procedures
(a) External control signal mode:
When the cycle operation mode signal is turned on, the cycle operation mode
is selected. When the same signal is turned off, the continuous operation
mode takes effect.
For the cycle operation mode signal, see the Interface Manual.
(b) "EX. 232C" or "EX. ETHER" mode:
Specify the run mode by sending the MODE command as an internal
command for data communication (EC).
For details of sending the internal command, see the Communication
Manual.
(3) Cautions
In the external control signal mode, the run mode is selected by the cycle
operation mode signal.
In the "EX. 232C" mode and "EX. ETHER" mode, the cycle operation mode
signal is ineffective.
If the external automatic mode has replaced the internal automatic in the "EX.
232C" mode and "EX. ETHER" mode, the operation mode effective then is
maintained. To specify the run mode in the "EX.232C" mode and
"EX.ETHER" mode, send the MODE command as an internal command
through data communication.
In the external automatic mode, you cannot specify the run mode, using the
command through the teach pendant.