13
(C) Motor Constant Parameters
Purpose
To select the motor to be used
To maximize the performance of the
induction motor
To maximize the performance of the
PM motor
To perform high accuracy operation
without being affected by temperature
and high-torque/ultra-low speed
13.1

Applied motor

By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay function is set according to the motor.
When the Advanced magnetic flux vector control, Real sensorless vector control, or PM sensorless vector control is selected,
the motor constant necessary for control (SF-PR, SF-JR, SF-HR, SF-JRCA, SF-HRCA, GM-[], or GM-[]P) is also selected at
the same time.
Pr.
Name
71
Applied motor
C100
450
Second applied motor
C200
*1
The setting range for the 575 V class is "0, 3, 5, 6, 10, 13, 15, 16, 8090, 8093, 9090, and 9093".
304
13.(C) Motor Constant Parameters
13.1 Applied motor
Applied motor
P.C100, P.C200
P.C100 to P.C105,
P.C107, P.C108,
P.C110, P.C120 to
P.C126, P.C182,
Offline auto tuning
PC188, P.C200 to
P.C205, P.C207,
P.C208, P.C210,
P.C220 to P.C226,
P.C282, P.C288
P.C100 to P.C108,
P.C110, P.C120,
P.C122, P.C123,
P.C126, P.C130 to
P.C133, P.C135,
P.C150, P.C182,
PM motor offline auto
P.C185, P.C200 to
tuning
P.C208, P.C210,
P.C220, P.C222,
P.C223, P.C226,
P.C230 to P.C233,
P.C235, P.C282,
P.C285
Online auto tuning
P.C111, P.C211
Initial value
Setting range
0, 3, 5, 6, 10, 13, 15, 16, 20, 23,
40, 43, 50, 53, 70, 73, 1800,
0
1803, 8090, 8093, 9090, 9093
0, 3, 5, 6, 10, 13, 15, 16, 20, 23,
40, 43, 50, 53, 70, 73, 1800,
9999
1803, 8090, 8093, 9090, 9093
9999
Parameter to set
Pr.71, Pr.450
Pr.9, Pr.51, Pr.71,
Pr.80 to Pr.84, Pr.90 to
Pr.94, Pr.96, Pr.453 to
Pr.463, Pr.707, Pr.717,
Pr.720, Pr.724, Pr.737,
Pr.741, Pr.744, Pr.745,
Pr.859, Pr.860
Pr.9, Pr.51, Pr.71,
Pr.80, Pr.81, Pr.83,
Pr.84, Pr.90, Pr.92,
Pr.93, Pr.96, Pr.450,
Pr.453, Pr.454, Pr.456
to Pr.458, Pr.460,
Pr.461, Pr.463, Pr.702,
Pr.706, Pr.707, Pr.711,
Pr.712, Pr.717, Pr.721,
Pr.724, Pr.725, Pr.738
to Pr.746, Pr.859,
Pr.860, Pr.1002,
Pr.1412, Pr.1413
Pr.95, Pr.574
By selecting a motor, the thermal characteristic
and motor constant of each motor are set.
*1
Set this parameter when using the second motor
(the same specifications as Pr.71).
*1
The function is disabled.
Refer to page
304
309
318
325
Description

Advertisement

Table of Contents
loading

Table of Contents