Mitsubishi Electric 800 Series Instruction Manual page 96

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• Performing Parameter clear or All parameter clear resets these parameter settings to the settings required to drive an
induction motor.
Pr.
Name
1
Maximum frequency
4
Multi-speed setting (high speed)
9
Electronic thermal O/L relay
13
Starting frequency
15
Jog frequency
Acceleration/deceleration reference
20
frequency
22
Stall prevention operation level
Frequency / rotation speed unit
53
switchover
55
Frequency monitoring reference
56
Current monitoring reference
71
Applied motor
72
PWM frequency selection
80
Motor capacity
81
Number of motor poles
84
Rated motor frequency
125
Terminal 2 frequency setting gain
(903)
frequency
126
Terminal 4 frequency setting gain
(905)
frequency
240
Soft-PWM operation selection
374
Overspeed detection level
390
% setting reference frequency
505
Speed setting reference
Current average value monitor
557
signal output reference current
800
Control method selection
820
Speed control P gain 1
821
Speed control integral time 1
Torque control P gain 1 (current loop
824
proportional gain)
Torque control integral time 1
825
(current loop integral time)
870
Speed detection hysteresis
Regeneration avoidance
885
compensation frequency limit value
Energy saving monitor reference
893
(motor capacity)
—: Not changed
*1
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
*2
120% for LD rating and 150% for ND rating (Refer to Pr.570 Multiple rating setting on
*3
The Pr.702 Maximum motor frequency is used as the maximum motor frequency (rotations per minute). When Pr.702 = "9999" (initial value),
the Pr.84 Rated motor frequency is used as the maximum motor frequency (rotations per minute).
*4
The setting value is converted from frequency to rotations per minute. (It differs according to the number of motor poles.)
NOTE
• When the motor parameter initialization is performed with the setting in units of rotations per minute (Pr.998 = "8009 or 9009"),
the parameters not listed in the table and the monitor items are also set and displayed in rotations per minute.
Setting
PM motor
Induction motor
(rotations per
minute)
*1
0 (initial value)
8009, 9009
Gr.1
Gr.2
Maximum motor
rotations per
120 Hz
*3
minute
60 Hz
50 Hz
Pr.84
Inverter rated current
0.5 Hz
Pr.84 × 10%
5 Hz
Pr.84 × 10%
60 Hz
50 Hz
Pr.84
*2
*2
150%
150%
0
1
60 Hz
50 Hz
Pr.84
Inverter rated current
Pr.859
0
2
9999
9999
9999
60 Hz
50 Hz
Pr.84
60 Hz
50 Hz
Pr.84
1
0
Maximum motor
rotations per minute
9999
+ 10 Hz
60 Hz
50 Hz
Pr.84
60 Hz
50 Hz
Inverter rated current
Pr.859
40
10
60%
30%
0.333 s
0.333 s
100%
100%
5 ms
20 ms
*4
0 Hz
0.5 Hz
6 Hz
Pr.84 × 10%
Motor capacity
Inverter rated current
(Pr.80)
page
50.)
PM motor
(frequency)
8109, 9109
Maximum motor
*3
frequency
Pr.84
Pr.84 × 10%
Pr.84 × 10%
Pr.84
*2
150%
0
Pr.84
Pr.859
2
Pr.84
Pr.84
0
Maximum motor
frequency + 10 Hz
*3*4
Pr.84
Pr.859
10
30%
0.333 s
100%
20 ms
0.5 Hz
Pr.84 × 10%
Motor capacity
(Pr.80)
page
140.)
4.3 Selecting the PM sensorless vector control
Setting increments
8009,
0, 8109,
9009
9109
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.01 A
0.01 A
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.1%
0.1%
1
1
1 r/min
0.01 Hz
0.01 A
0.01 A
1
1
1
1
0.01 kW
0.01 kW
1
1
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1 r/min
0.01 Hz
1
1
1 r/min
0.01 Hz
*3
10
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.01 A
0.01 A
1
1
1%
1%
0.001 s
0.001 s
1%
1%
0.1 ms
0.1 ms
1 r/min
0.01 Hz
1 r/min
0.01 Hz
0.01 kW
0.01 kW
95
4. Control Method
1
2
3
4
5
6
7
8
9