 Initial setting with the GOT2000 series
• When "FREQROL 500/700/800, SENSORLESS SERVO" is selected for "Controller Type" in the GOT setting, set Pr.999
= "10" to configure the GOT initial setting.
• When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT setting, the GOT automatic
connection can be used. When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT
setting and the GOT automatic connection is not used, set Pr.999 = "12" to configure the GOT initial setting. (Refer to the
Instruction Manual (Communication).)
 Initial setting with the GOT1000 series
• Set Pr.999 = "10" to configure the GOT initial setting.
NOTE
• Always perform an inverter reset after the initial setting.
• For the details of connection with GOT, refer to the Instruction Manual of GOT.
 Rated frequency (Pr.999 = "20" (50 Hz) or "21" (60 Hz))
Pr.
Name
3
Base frequency
4
Multi-speed setting (high speed)
Acceleration/deceleration reference
20
frequency
Frequency / rotation speed unit
53
switchover
55
Frequency monitoring reference
Stall prevention operation reduction
66
starting frequency
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
390
% setting reference frequency
505
Speed setting reference
808
Speed limit
*1
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
*2
Refer to the Instruction Manual (Communication).
NOTE
• When the plug-in option FR-A8AX is used, Pr.301 BCD input gain and Pr.303 BIN input gain are not set automatically.
*1
Initial value
Gr.1
Gr.2
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
0
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
page
50).
Pr.999 = "21"
Pr.999 = "20"
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
0
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
7. (E) Environment Setting Parameters
7.12 Setting multiple parameters by batch
1
2
3
4
5
Refer to
6
page
386
202
7
164
234
245
8
222
9
282
*2
10
234
122
149

Advertisement

Table of Contents
loading

Table of Contents