Mitsubishi Electric 800 Series Instruction Manual page 204

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Multi-speed setting for 4th speed or more (Pr.24 to Pr.27, Pr.232 to Pr.239)
• The frequency from 4th speed to 15th speed can be set according to the combination of the RH, RM, RL, and REX signals.
Set the frequencies in Pr.24 to Pr.27, Pr.232 to Pr.239. (In the initial status, 4th to 15th speeds are invalid.)
• To input the REX signal, set "8" in any parameter from Pr.178 to Pr.189 (Input terminal function selection) to assign the
function.
Forward
Inverter
rotation
STF
REX
RH
RM
RL
SD
*1
When the RH, RM and RL signals are OFF and the REX signal is ON while "9999" is set to Pr.232 Multi-speed setting (speed 8), the inverter
operates at the frequency set in Pr.6.
NOTE
• The priority of the frequency commands given by the external signals are as follows: JOG operation > multi-speed operation
> terminal 4 analog input > terminal 2 analog input. (For details on frequency commands given by analog input, refer to
282.)
• The input compensation of multi-speed setting is enabled when the inverter is in the External operation mode or PU/External
combined operation mode (Pr.79 = "3 or 4").
• Multi-speed parameters can also be set during PU operation or External operation.
• The Pr.24 to Pr.27 and Pr.232 to Pr.239 settings have no priority among them.
• When Pr.59 Remote function selection ≠ "0", the multi-speed setting is invalid since the RH, RM, and RL signals are for
remote setting.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other functions.
Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.15 Jog
frequencypage 200
Pr.59 Remote function
selectionpage 171
Pr.79 Operation mode
selectionpage 180
Pr.178 to Pr.189 (Input terminal function
Speed 4
RH
RM
RL
REX
selection)page 292
Speed 10
Speed 5
Speed 6
Speed 9
Speed 8
Speed 7
ON ON ON
ON ON
ON
ON
ON
ON
ON
ON
ON
ON
ON ON ON ON ON ON
∗1
9. (D) Operation Command and Frequency Command
9.6 Operation by multi-speed setting
Speed 11
Speed 12
Speed 13
Speed 14
Speed 15
Time
ON ON ON ON
ON ON
ON
ON
ON
page
1
2
3
4
5
6
7
8
9
10
203

Advertisement

Table of Contents
loading

Table of Contents