(D) Operation Command and Frequency
Command
Purpose
To select the operation mode
To start up the inverter in Network operation
mode at power-ON
To select the command source during
communication operation
To prevent the motor from rotating
reversely
To change the setting resolution of the
torque limit
To perform JOG (inching) operation
To control the frequency with combinations
of terminals
To select the torque command method
during torque control
9.1

Operation mode selection

Select the operation mode of the inverter.
The mode can be changed among operation using external signals (External operation), operation by the operation panel (PU
operation), combined operation of PU operation and External operation (External/PU combined operation), and Network
operation (via RS-485 communication or Ethernet communication, or when a communication option is used).
Pr.
79
Operation mode selection 0
D000
The following table lists valid and invalid commands in each operation mode.
180
9. (D) Operation Command and Frequency Command
9.1 Operation mode selection
Operation mode selection P.D000
Communication startup
mode selection
Operation and speed
command sources during
communication operation,
command source
selection
Reverse rotation
prevention selection
Set resolution switchover P.D030
JOG operation
Multi-speed operation
Torque command source
selection
Name
Initial value
Parameter to set
P.D000, P.D001
P.D010 to P.D013
P.D020
P.D200, P.F002
P.D301 to P.D315
P.D400 to P.D402
Setting range
0 to 4, 6, 7
Selects the operation mode.
Refer to
page
Pr.79
180
Pr.79, Pr.340
190
Pr.338, Pr.339, Pr.550,
191
Pr.551
Pr.78
199
Pr.811
234
Pr.15, Pr.16
200
Pr.4 to Pr.6, Pr.24 to
202
Pr.27, Pr.232 to Pr.239
Pr.804 to Pr.806
119
Description