• When the remotely-set frequency is cleared by turning ON the clear (RL) signal after turning OFF (ON) both the RH and RM
signals, the inverter operates at the frequency in the remotely-set frequency cleared state if power is reapplied before one
minute has elapsed since turning OFF (ON) both the RH and RM signals.
CAUTION
• When using the remote setting function, set the maximum frequency again according to the machine.
Parameters referred to
Pr.1 Maximum frequency, Pr.18 High speed maximum
Pr.7 Acceleration time, Pr.8 Deceleration time, Pr.44 Second acceleration/deceleration time, Pr.45 Second deceleration
Pr.178 to Pr.189 (Input terminal function
174
8. (F) Settings for Acceleration/Deceleration
8.3 Remote setting function
Remotely-set frequency stored last time
ON
Acceleration (RH)
Deceleration (RM) OFF
Clear (RL)
ON
Forward rotation (STF)
ON
Power supply
frequencypage 219
selection)page 292
One minute
More than
one minute
Operation is performed at the set
frequency 0Hz.
Time
ON
ON
ON
timepage 164