Mitsubishi Electric 800 Series Instruction Manual page 324

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Parameters updated by tuning results after tuning
First
Second
motor Pr.
motor Pr.
90
458
Motor constant (R1)
92
460
Motor constant (L1)/d-axis inductance (Ld)
93
461
Motor constant (L2)/q-axis inductance (Lq)
711
739
Motor Ld decay ratio
712
740
Motor Lq decay ratio
717
741
Starting resistance tuning compensation coefficient 1
721
742
Starting magnetic pole position detection pulse width
859
860
Torque current/Rated PM motor current
96
463
Auto tuning setting/status
 Tuning adjustment (Pr.1002)
• The overcurrent protective function may be activated during Lq tuning for an easily magnetically saturated motor (motor
with a large Lq decay ratio). In such case, adjust the target flowing current used for tuning with Pr.1002 Lq tuning target
current adjustment coefficient.
 Changing the motor constants
• The motor constants can be set directly when the motor constants are known in advance, or by using the data measured
during offline auto tuning.
• According to the Pr.71 (Pr.450) setting, the range of the motor constant parameter setting values and units can be
changed. The changed settings are stored in the EEPROM as the motor constant parameters.
 Changing the motor constants (when setting motor constants in units of
Ω, mH, or A)
• Set Pr.71 as follows.
Motor
Pr.71 setting
IPM motor
8090
SPM motor
9090
• Set desired values as the motor constant parameters.
First
Second
motor Pr.
motor Pr.
90
458
Motor constant (R1)
92
460
Motor constant (L1)/d-axis inductance (Ld)
93
461
Motor constant (L2)/q-axis inductance (Lq)
706
738
Induced voltage constant (phi f)
859
860
Torque current/Rated PM motor current
1412
1413
Motor induced voltage constant (phi f) exponent
NOTE
• If "9999" is set in the motor constant parameters, tuning data will be invalid and the inverter internal constant is used.
• To change a motor induced voltage constant of PM motors, the setting in Pr.706 Induced voltage constant (phi f) or Pr.738
Second motor induced voltage constant (phi f) must be changed. If the constant after the change exceeds the setting range
of Pr.706 or Pr.738 (0 to 5000 mV (rad/s)), set Pr.1412 Motor induced voltage constant (phi f) exponent or Pr.1413
Second motor induced voltage constant (phi f) exponent. Set a value in the exponent n in the formula, Pr.706 (Pr.738) ×
n
10
[mV (rad/s)], to set the induced voltage constant (phi f).
• When Pr.71 (Pr.450) = "8093 or 9093", or Pr.1412 (Pr.1413) = "9999", the motor induced voltage constant is as set in Pr.706
(Pr.738). (No exponent setting)
Name
Name
0 to 50 Ω, 9999
0 to 500 mH, 9999
0 to 500 mH, 9999
0 to 5000 mV (rad/s), 9999 0.1 mV (rad/s)
0 to 500 A, 9999
0 to 2, 9999
13.3 Offline auto tuning for a PM motor (motor constant tuning)
Description
Resistance per phase
d-axis inductance
q-axis inductance
d-axis inductance decay ratio
q-axis inductance decay ratio
Setting
Setting range
increments
0.001 Ω
0.01 mH
0.01 mH
0.01 A
1
13.(C) Motor Constant Parameters
11
12
13
14
15
16
17
18
19
20
Initial value
9999
323