Pr. group
Pr.
M464
167
M470
864
 T: Multi-function input terminal
parameters
Parameters for the setting of the input terminals via which
commands are given to the inverter.
Pr. group
Pr.
T000
73
T001
267
T002
74
T003
822
T004
826
T005
832
T006
836
T007
849
T022
125
T040
858
T042
126
C2
T200
*1
(902)
C3
T201
*1
(902)
125
T202
*1
(903)
C4
T203
*1
(903)
C5
T400
*1
(904)
C6
T401
*1
(904)
126
T402
*1
(905)
C7
T403
*1
(905)
C38
T410
*1
(932)
C39
T411
*1
(932)
C40
T412
*1
(933)
C41
T413
*1
(933)
T700
178
T701
179
T702
180
T703
181
T704
182
80
3. Parameters
3.4 Parameter list (by function group number)
Name
Output current detection
operation selection
Torque detection
Name
Analog input selection
Terminal 4 input selection
Input filter time constant
Speed setting filter 1
Torque setting filter 1
Speed setting filter 2
Torque setting filter 2
Analog input offset adjustment
Terminal 2 frequency setting
gain frequency
Simple
Simple
Simple
Terminal 4 function
assignment
Terminal 4 frequency setting
gain frequency
Simple
Simple
Simple
Terminal 2 frequency setting
bias frequency
Terminal 2 frequency setting
bias
Terminal 2 frequency setting
gain frequency
Terminal 2 frequency setting
gain
Terminal 4 frequency setting
bias frequency
Terminal 4 frequency setting
bias
Terminal 4 frequency setting
gain frequency
Terminal 4 frequency setting
gain
Terminal 4 bias command
(torque/magnetic flux)
Terminal 4 bias (torque/
magnetic flux)
Terminal 4 gain command
(torque/magnetic flux)
Terminal 4 gain (torque/
magnetic flux)
STF/DI0 terminal function
selection
STR/DI1 terminal function
selection
RL terminal function selection
RM terminal function selection
RH terminal function selection
Refer
Pr. group
Pr.
to page
268
T709
183
270
T711
184
T720
17
T740
699
T751
185
T752
186
T753
187
Refer
T754
188
to page
T755
189
274
274
 C: Motor constant parameters
280
Parameters for the applied motor setting.
280
280
Pr. group
Pr.
280
280
C100
71
280
282
C101
80
102,
222,
C102
81
279
C103
9
282
282
C104
83
282
C105
84
C106
702
282
C107
707
C108
724
282
C110
96
282
C111
95
282
C120
90
282
C121
91
282
C122
92
C123
93
282
C124
94
282
C125
82
C126
859
282
C130
706
287
C131
711
292
C132
712
C133
725
292
C135
1412
292
C150
1002
292
C182
717
292
Name
MRS terminal function
selection
RES terminal function
selection
MRS/X10 terminal input
selection
Input terminal filter
NET X1 input selection
NET X2 input selection
NET X3 input selection
NET X4 input selection
NET X5 input selection
Name
Applied motor
Motor capacity
Number of motor poles
Rated motor current
Simple
Simple
Simple
Rated motor voltage
Rated motor frequency
Maximum motor frequency
Motor inertia (integer)
Motor inertia (exponent)
Auto tuning setting/status
Online auto tuning selection
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis
inductance (Ld)
Motor constant (L2)/q-axis
inductance (Lq)
Motor constant (X)
Motor excitation current
Torque current/Rated PM
motor current
Induced voltage constant (phi
f)
Motor Ld decay ratio
Motor Lq decay ratio
Motor protection current level
Motor induced voltage
constant (phi f) exponent
Lq tuning target current
adjustment coefficient
Starting resistance tuning
compensation coefficient 1
Refer
to page
292
292
296
292
292
292
292
292
292
Refer
to page
304,
309,
318
88, 309,
318
88, 309,
318
206,
309,
318
88, 309,
318
88, 309,
318
318
318
318
309,
318,
369
325
309,
318,
369
309
309,
318
309,
318
309
309
309,
318
318
318
318
318
318
318
318

Advertisement