15.5

SF-PR slip amount adjustment mode

V/F
V/F
V/F
• As compared to our conventional SF-JR motor, the slip amount is small for the high-performance energy-saving SF-PR
motor. When replacing the SF-JR to the SF-PR, the slip amount is reduced and the rotations per minute increases.
Therefore, when the SF-PR is used with the same frequency setting as that of the SF-JR, power consumption may
increase as compared to the SF-JR.
• By setting the slip amount adjustment mode, the frequency command can be adjusted to keep the rotations per minute of
the SF-PR equivalent to those of the SF-JR for power consumption reduction.
Pr.
Name
673
SF-PR slip amount adjustment
*1
operation selection
G060
674
SF-PR slip amount adjustment
*1
gain
G061
*1
The setting is available only for the 200/400 V class.
• By setting the number of SF-PR motor poles in Pr.673 SF-PR slip amount adjustment operation selection, the SF-PR
slip amount adjustment mode is activated.
• The SF-PR slip amount adjustment mode is available only under V/F control.
• Use Pr.674 SF-PR slip amount adjustment gain to fine-tune the rotations per minute. To reduce the rotations per minute
(to increase the compensation frequency), set a larger value in Pr.674. To increase the rotations per minute (to reduce the
compensation frequency), set a smaller value in Pr.674. (Lower rotations per minute reduce the power consumption, and
higher rotations per minute increase the power consumption.)
NOTE
• The slip amount adjustment is not available in the following conditions.
During acceleration/deceleration, during DC injection brake operation, during PID control, during stall prevention operation,
during regeneration avoidance operation, during traverse operation, and while the slip compensation is valid (Pr.245).
• The slip amount adjustment is not available when the applicable motor capacity of the inverter is not compatible with the SF-
PR. (For the details of the applicable motor capacity, refer to the Instruction Manual (Connection).)
Initial value
Setting range
2, 4, 6
9999
9999
100%
0% to 500%
Description
Set the number of SF-PR motor poles.
The slip amount adjustment is disabled.
Setting is available for fine adjustment of the slip amount.
15.(G) Control Parameters
15.5 SF-PR slip amount adjustment mode
11
12
13
14
15
16
17
18
19
20
391