Mitsubishi Electric 800 Series Instruction Manual page 67

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Function
Pr.
group
792
F071
 Pr.800 to Pr.999
Function
Pr.
group
800
G200
801
H704
803
G210
804
D400
805
D401
806
D402
807
H410
808
H411
809
H412
810
H700
811
D030
812
H701
813
H702
814
H703
815
H710
816
H720
817
H721
820
G211
821
G212
822
T003
824
G213
825
G214
826
T004
830
G311
831
G312
832
T005
834
G313
835
G314
836
T006
66
3. Parameters
3.2 Parameter list (by parameter number)
Pr.
Name
Deceleration time in low-
speed range
Pr.
Name
Control method selection
Output limit level
Constant output range
torque characteristic
selection
Torque command source
selection
Torque command value
(RAM)
Torque command value
(RAM, EEPROM)
Speed limit selection
Speed limit
Reverse-side speed limit
Torque limit input method
selection
Set resolution switchover
Torque limit level
(regeneration)
Torque limit level (3rd
quadrant)
Torque limit level (4th
quadrant)
Torque limit level 2
Torque limit level during
acceleration
Torque limit level during
deceleration
Speed control P gain 1
Speed control integral time 1 0 to 20 s
Speed setting filter 1
Torque control P gain 1
(current loop proportional
gain)
Torque control integral time 1
(current loop integral time)
Torque setting filter 1
Speed control P gain 2
Speed control integral time 2 0 to 20 s, 9999
Speed setting filter 2
Torque control P gain 2
(current loop proportional
gain)
Torque control integral time 2
(current loop integral time)
Torque setting filter 2
Minimum
Setting range
setting
increments
0 to 3600 s, 9999
0.1 s
Minimum
Setting range
setting
increments
10 to 12, 19, 20, 40
1
0% to 400%, 9999
0.1%
0 to 2, 10
1
0, 1, 3 to 6
1
600% to 1400%
1%
600% to 1400%
1%
0, 1
1
0 to 400 Hz
0.01 Hz
0 to 400 Hz, 9999
0.01 Hz
0 to 2
1
0, 10
1
0% to 400%, 9999
0.1%
0% to 400%, 9999
0.1%
0% to 400%, 9999
0.1%
0% to 400%, 9999
0.1%
0% to 400%, 9999
0.1%
0% to 400%, 9999
0.1%
0% to 1000%
1%
0.001 s
0 to 5 s, 9999
0.001 s
0% to 500%
1%
0 to 500 ms
0.1 ms
0 to 5 s, 9999
0.001 s
0% to 1000%, 9999
1%
0.001 s
0 to 5 s, 9999
0.001 s
0% to 500%, 9999
1%
0 to 500 ms, 9999
0.1 ms
0 to 5 s, 9999
0.001 s
Initial
Refer
Customer
*1
value
to page
setting
Gr.1
Gr.2
9999
164
Initial
Refer
Customer
*1
value
to page
setting
Gr.1
Gr.2
40
88
102,
9999
119
102,
0
119
0
119
1000%
119
1000%
119
0
122
60 Hz 50 Hz
122
9999
122
0
102
0
102
9999
102
9999
102
9999
102
9999
102
9999
102
9999
102
60%
109
0.333 s
109
9999
280
100%
124
5 ms
124
9999
280
9999
109
9999
109
9999
280
9999
124
9999
124
9999
280

Advertisement

Table of Contents
loading

Table of Contents