 Input signal list
• Refer to the following table and set the parameters.
Signal
Setting
name
Pr.59 = "0" (initial value)
0
RL
Pr.59 ≠ "0"
Pr.270 = "1, 11"
Pr.59 = "0" (initial value)
1
RM
Pr.59 ≠ "0"
Pr.59 = "0" (initial value)
2
RH
Pr.59 ≠ "0"
Second function selection
3
RT
Pr.270 = "1, 11"
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection (Available for the standard model only)
7
OH
External thermal relay input
15-speed selection (Combination with multi-speeds of RL, RM, and
8
REX
RH)
10
X10
Inverter run enable (FR-XC/FR-HC2/FR-CV connection)
12
X12
PU operation external interlock
14
X14
PID control valid
15
BRI
Brake opening completion
16
X16
PU/External operation switchover (External operation with X16-ON) Pr.79, Pr.340
18
X18
V/F switchover (V/F control with X18-ON)
24
MRS
Output stop
STP
25
Start self-holding selection
(STOP)
26
MC
Control mode switchover
27
TL
Torque limit selection
30
JOG2
37
X37
Traverse function selection
46
TRG
Trace trigger input
47
TRC
Trace sampling start/end
50
SQ
Sequence start
51
X51
Fault clear
Forward rotation command (assignable to the STF terminal
60
STF
(Pr.178) only)
Reverse rotation command (assignable to the STR terminal
61
STR
(Pr.179) only)
62
RES
Inverter reset
65
X65
PU/NET operation switchover (PU operation with X65-ON)
66
X66
External/NET operation switchover (NET operation with X66-ON)
Command source switchover (command by Pr.338 or Pr.339
67
X67
enabled with X67-ON)
72
X72
PID P control switchover
92
X92
Emergency stop
9999
-
No function
*1
When Pr.59 Remote function selection ≠ "0", functions of the RL, RM, and RH signals are changed as shown in the table.
*2
When Pr.270 Stop-on-contact control selection = "1 or 11", functions of the RL and RT signals are changed as shown in the table.
*3
The OH signal is activated when the relay contact is open.
Function
Low-speed operation command
*1
Remote setting (setting clear)
*2
Stop-on-contact selection 0
Middle-speed operation
command
*1
Remote setting (deceleration)
High-speed operation command
*1
Remote setting (acceleration)
*2
Stop-on-contact selection 1
*3
Related parameter
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.270, Pr.275, Pr.276
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
Pr.44 to Pr.48, Pr.51, Pr.450
to Pr.463, Pr.569, Pr.832,
Pr.836, etc.
Pr.270, Pr.275, Pr.276
Pr.267
Pr.15, Pr.16
Pr.9
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.17, Pr.30, Pr.70
Pr.79
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.278 to Pr.283
Pr.80, Pr.81, Pr.800
Pr.17
Pr.250
Pr.800
Pr.815
Pr.15, Pr.16
Pr.592 to Pr.597
Pr.1020 to Pr.1047
Pr.1020 to Pr.1047
Pr.414
Pr.414
Pr.250
Pr.250
Pr.75
Pr.79, Pr.340
Pr.79, Pr.340
Pr.338, Pr.339
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.1103
12.(T) Multi-Function Input Terminal Parameters
12.6 Input terminal function selection
11
12
Refer to
page
202
13
171
334
202
14
171
202
15
171
298
16
334
274
200
17
206
202
18
396
180
339
19
330
180
88
296
20
300
88
102
200
337
377
377
373
373
300
300
131
180
180
191
339
164
293

Advertisement

Table of Contents
loading

Table of Contents