Mitsubishi Electric 800 Series Instruction Manual page 247

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Monitor item
Electronic thermal O/L
relay load factor
Output current peak
value
Converter output voltage
peak value
Input power
*1
Output power
Load meter
Motor excitation current
Reference voltage output —
Motor load factor
Torque command
Torque current command 0.1%
Motor output
Energy saving effect
PID set point
PID measured value
PID deviation
Motor thermal load factor 0.1%
Inverter thermal load
factor
PID measured value 2
PLC function analog
output
PID manipulated amount 0.1%
Dancer main speed
setting
*1
The inverter regards the output current which is less than the specified current level (5% of the rated inverter current) as 0 A. Therefore, each
readout of an output current and output power may show "0" if a too small-capacity motor is used as contrasted with the inverter capacity and the
output current falls below the specified value.
*2
The setting is available only in Pr.158 (terminal AM).
 Frequency monitor reference (Pr.55)
• Enter the full scale value of a meter used to monitor the output frequency, frequency setting value, or dancer main speed
setting via terminal FM or terminal AM.
• For the FM type inverter, enter the full-scale value of the meter corresponding to a pulse train of 1440 pulses/s output via
terminal FM. Enter the frequency value (for example, 60 Hz or 120 Hz) at full scale of the meter (1 mA analog meter)
installed between terminal FM and terminal SD. Pulse speed is proportional to the output frequency of the inverter. (The
maximum pulse train output is 2400 pulses/s.)
246
11.(M) Item and Output Signal for Monitoring
11.3 Monitor display selection for terminals FM and AM
Pr.54 (FM),
Increment and
Pr.158 (AM)
unit
setting
0.1%
10
0.01 A
11
0.1 V
12
0.01 kW
13
0.01 kW
14
0.1%
17
0.01 A
18
21
0.1%
24
0.1%
32
33
0.01 kW
34
Increment and unit
vary depending on
50
the parameter
settings.
0.1%
52
0.1%
53
*2
0.1%
54
61
0.1%
62
0.1%
67
0.1%
70
*2
91
0.01 Hz.
97
Terminal FM/AM
Negative
full-scale value
output
Electronic thermal O/
L relay (100%)
Pr.56
200 V class: 400 V,
400 V class: 800 V,
575 V class: 1000 V
Inverter rated power ×
2
Inverter rated power ×
2
Pr.866
Pr.56
200%
Pr.866
Pr.866
Rated motor capacity
Inverter capacity
100%
100%
100%
Motor thermal
activation level
(100%)
Inverter thermal
activation level
(100%)
100%
100%
100%
Pr.55
Remarks
Terminal FM: 1440 pulse/s is
output.
Terminal AM: Output is 10 V.
For the information of the power
saving effect monitoring, refer to
page
252.
Refer to
page 348
for the PID
control.
Refer to
page 348
for the PID
control.
Enabled when Pr.414 ≠ "0".
Refer to
page 375
for the PLC
function.
Refer to
page 348
for the PID
control.
For details on dancer control, refer
to
page
355.