7.2.1
CONFigure Sub-system
CONFigure
:AUTO
:LOAD
:MODE
:DISPlay
:KEY
:REMote
:SAVE
:SOUNd
:VOLTage
:LATch
:RESet
:ON
:POLarity
:RANGe
CONFigure:AUTO:LOAD
Description Set if the load module will do Auto Load On during power-on.
Syntax CONFigure:AUTO:LOAD <NR1 | CHAR>
Parameters 0 | OFF, 1 | ON
Example CONF:AUTO:LOAD ON
Query Syntax CONFigure:AUTO:LOAD?
Return Parameters 0 | 1
Query Example CONF: AUTO: LOAD?
Return Example 0 (OFF)
CONFigure:AUTO:MODE
Description Set type of Auto Load On as LOAD ON or PROGRAM ON.
Syntax CONFigure:AUTO:MODE <NR1 | CHAR>
Parameters 0 | PROGRAM, 1 | LOAD
Example CONF:AUTO:MODE LOAD
Query Syntax CONFigure:AUTO:MODE?
Return Parameters 0 | 1
Query Example CONF:AUTO:MODE?
Return Example 0 ( PROGRAM)
CONFigure:DISPlay
Description Set measure display mode
Command Syntax CONFigure:DISPlay <NR1 | CHAR>
CONF:AUTO:LOAD OFF Close Auto Load On during power on.
CONF:AUTO:MODE PROGRAM
Language Dictionary
Start Auto Load On during power on.
Return the status of Auto Load On
Set Auto Load On as general
Load On.
Set Auto Load On as
Program On.
Return the execution type of
Auto Load On.
7-5