2.
Setting the Sequence Mode
There are three modes to control the method of sequence execution.
SKIP:
Skip the sequence. Load will not change the input status.
AUTO:
Use ON/OFF time to control Load input on/off. When ON/OFF time
passes, the Load will get to the next sequence automatically.
MANUAL:
Use ▲, ▼ or number 0 to 9 to control the execution sequence. Pressing
number key lets you select a random sequence number to execute.
Pressing
Press
,
2
ENTER
settings for one program. The default setting is SKIP.
3.
Setting the Sequence Load ON/OFF Time
The sequence ON/OFF time controls the Load input ON/OFF when the program's
sequence is executed. The ON/OFF time range is 0 to 60 seconds. (30S each)
Press
,
8
ENTER
OFF time.
4.
Setting the Short Delay/ON Time
The range of short delay and on time is from 0 to 60 Sec. The short delay time starts
from the beginning of the Load on time. If the short time is set to 0 Sec., the Load will
not short. The default setting is 0 Sec.
Press
,
8
ENTER
means to go to sequence 10.
0
keys to set sequence 1 to manual mode. You need to set ten sequence
[ SEQ 1 ]
0: SKIP
SEQUENCE 1
LOAD ON TIME : 20.0 S
keys to set OFF time for 8 seconds. The default setting is 0 second for
SEQUENCE 1
LOAD OFF TIME : 8.0 S
SEQUENCE 1
SHORT DELAY :
to set SHORT on time for 8 seconds.
1: AUTO
2: MANUAL
0.0 S
Local Operation
4-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

632016320263203632046320563206 ... Show all

Table of Contents