Description This command returns the status of the electronic load.
Query Syntax LOAD:PROTection:CLEar?
Return Parameters <NR1>
Bit Position 15 14 13 12 11 10
Condition
0
Bit Weight
Query Example LOAD:PROT?
Return Example 0
LOAD:PROTection:CLEar
Description This command resets status of the electronic load.
Syntax LOAD:PROTection:CLEar
Parameters For valid value range refer to respective specification.
Example LOAD:PROT:CLE
LOAD:SAVE
Description This command saves the present state of electronic load as default.
Syntax LOAD:SAVE
Parameters None
Example LOAD:SAVE
7-16
0
0
0
0
0
9
8
7
6
5
0
0
0
0
0 OT RV OP OV OC
16
Return the status of the electronic load.
4
3
2
1
0
8
4
2
1