7.2.13 VOLTage Sub-system

VOLTage
:CURRent
:L1
:L2
:MODE
VOLTage:CURRent
Description Set the current limit for constant voltage mode.
Syntax VOLTage:CURRent
Parameters For valid value range refer to respective specification.
Example VOLT:CURR 3
Query Syntax VOLTage:CURRent?
Return Parameters <NR2> [Unit=Ampere]
Query Example VOLT:CURR?
Return Example 3
VOLTage:L1/L2
Description Set voltage of static load during constant voltage mode.
Syntax VOLTage:L1
Parameters For valid value range refer to respective specification.
Example VOLT:L1 8V
Query Syntax VOLTage:L1?
Return Parameters <NR2> [Unit=Voltage]
Query Example VOLT:L1?
Return Example 0
VOLTage:MODE
Description Set the response speed of CV mode.
Syntax VOLTage:MODE <NR1 | CHAR>
Parameters 0 | SLOW, 1 | FAST
Example VOLT: MODE 1
VOLT:CURR MAX
VOLT:CURR MIN
VOLTage:L2
VOLT:L2 24V
VOLT:L1 MAX
VOLT:L2 MIN
VOLTage:L2?
VOLTage:L1? MAX
VOLT:L2? MIN
VOLT:MODE SLOW
Set loading current limit to 3A during
constant voltage mode.
Set loading current limit to the max.
value during constant voltage mode.
Set loading current limit to the min.
value during constant voltage mode.
Set the voltage of load L1 to 8V.
Set the voltage of load L2 to 24V.
Set the voltage of load L1 to the max. value.
Set the voltage of load L2 to the min. value.
Return the set voltage value of load L1.
Language Dictionary
7-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

632016320263203632046320563206 ... Show all