7.2.7

MODE Sub-system

MODE
MODE
Description This command sets operational modes of the electronic load.
Syntax MODE <NR1 | CHAR
Parameters 0 | CCL, 1 | CCH, 2 | CCDL, 3 | CCDH, 4 | CRL, 5 | CRH,
Example MODE CPL
Query Syntax MODE?
Return Parameters <NR1>
Query Example MODE?
Return Example 1 (CCH)
6 | CVL, 7 | CVH, 8 | CPL, 9 | CPH, 10 | CCEL, 11 | CCEH.
MODE 5
Set CP mode to low range
Set CR mode to high range
Return the operational mode of the
electronic load.