Setting CP Values
The CP mode for the Load is programmed by pressing
programmed in low current (CPL) or high current (CPH) range. All power levels are
programmed in Walt. The slew rate is in A/µS.
The following examples illustrate how to set CP values for Load model number 63203.
1.
Select range
Press
key to choose the high range CP mode.
RANGE
If press
RANGE
2.
Set Power Level
Set level A power level to 200 W by pressing
Set level B power level to 4000 W by pressing
3.
Set Slew Rate
Set the rise 20 A/µS and fall slew rates to 0.5A/µS by pressing
,
,
,
0
.
5
ENTER
4.
Set Voltage spec
Set the high voltage spec. to 6 V by pressing
Set the low voltage spec. to 4 V by pressing
CPHA :
CPHB :
again, it will go back to the low range CP mode
CPHA :
CPHB :
for fall slew rate.
CPH
:
CPH
:
CPH VOLTAGE SPEC.
HIGH :
CPH VOLTAGE SPEC.
LOW :
. The power values can be
CP
12.000W
12.000W
,
,
,
.
2
0
0
ENTER
,
,
,
,
4
0
0
0
ENTER
200.000W
4000.000W
,
2
20.0A/uS
0.5A/uS
,
.
6
ENTER
6.000V
,
.
4
ENTER
4.000V