Load Sub-System - Chroma 63200 Series Operation & Programming Manual

High power dc electronic load
Hide thumbs Also See for 63200 Series:
Table of Contents

Advertisement

7.2.5

LOAD Sub-system

LOAD
[:STATe]
:SHORt
[:STATe]
:KEY
:PROTection
:CLEar
:SAVE
LOAD[:STATe]
Description The LOAD command makes the electronic load active on or off.
Syntax LOAD:[STATe] <NR1 | CHAR >
Parameters 0 | OFF, 1 | ON
Example LOAD ON
Query Syntax LOAD:[STATe]?
Return Parameters 0 | 1
Query Example LOAD?
Return Example 1 (ON)
LOAD:SHORt[:STATe]
Description Activate or inactivate short-circuited simulation.
Syntax LOAD:SHORt:[STATe <NR1 | CHAR >]
Example LOAD:SHOR 1
Parameters 0 | OFF, 1 | ON
Query Syntax LOAD:SHORt:[STATe]?
Return Parameters 0 | 1
Query Example LOAD:SHOR?
Return Example 1 (ON)
LOAD:SHORt:KEY
Description Set the short key mode in the electronic load.
Syntax LOAD:SHORt:KEY TOGGLE <NR1 | CHAR >
Parameters 0 | HOLD, 1 | TOGGLE
Example LOAD:SHOR:KEY TOGGLE
Query Syntax LOAD:SHORt:KEY?
Return Parameters 0 | 1
Query Example LOAD:SHOR:KEY?
Return Example 1 (TOGGLE)
LOAD:PROTection?
LOAD OFF
LOAD:SHOR OFF
LOAD:SHOR:KEY 0
Activate the electronic load.
Inactivate the electronic load.
Return if the electronic load is active.
Activate short-circuited simulation.
Inactivate short-circuited simulation.
Return the short-circuit simulation state.
Set short key mode to Toggle.
Set short key mode to Hold.
Return the short key mode in the
electronic load.
Language Dictionary
7-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

632016320263203632046320563206 ... Show all

Table of Contents