Going To Local; Setting System And Rs-232C Connection - Chroma 63200 Series Operation & Programming Manual

High power dc electronic load
Hide thumbs Also See for 63200 Series:
Table of Contents

Advertisement

High Power DC Electronic Load 63200 Series Operation & Programming Manual
Press
,
to save program.
1
ENTER
4.2.8

Going To Local

The
CONF./LOCAL
You can press
CONF./LOCAL
local operation,
CONF./LOCAL
4.2.9

Setting System and RS-232C Connection

GPIB Address setting. Press
RS485 Address setting. Press
setting the models ID when used in parallel mode.
RS-232C parameters setting. There are four parameters for you to set: Baud Rate, Parity
Check and Data Bit number.
Baud Rate:
0:4800, 1:9600, 2:19200, 3:38400, 4:57600, 5: 115200 bits/second
Parity Check:
0: NONE, 1: EVEN, 2: ODD
Data Bit:
1: 7 bits, 2: 8 bits
Stop Bit:
1: 1 bit, 2: 2 bits
The RS-232C connector on the rear panel is a 9-pin connector (DB-9, male connector). The
RS-232C connector bus signal is defined as below.
4-18
SAVE
1: YES
key operates as local key when Electronic Load is in remote mode.
key to go to local operation when Load is in remote state. In
key operates as
,
8
ENTER
GPIB ADDRESS
,
3
ENTER
RS485 ADDRESS
PROGRAM
2: NO
key.
CONF
to set the Load GPIB address to 8.
8
to set the Load RS485 address to 3. This is for
3