High Power DC Electronic Load 63200 Series Operation & Programming Manual
Query Example SYST:PAR:SLAV:CHAN?
Return Example 0
SYSTem:PARallel:SLAVe:MODEl
Description Set parallel for slave model.
Syntax SYSTem:PARallel:SLAVe:MODEl <NR1 | CHAR>
Parameters 0 | NONE
Example SYST:PAR:SLAV:MODE 0
Query Syntax SYSTem:PARallel:SLAVe:MODEl?
Return Parameters 0~10
Query Example SYST:PAR:SLAV:MODE?
Return Example 0 (NONE)
7-34
1 | M63201,
2 | M63202,
3 | M63203,
4 | M63204,
5 | M63206,
6 | M63208,
7 | M63205,
8 | M63207,
9 | M63209,
10 | M63210
SYST:PAR:SLAV:MODE M63203