Chapter 5
LM: Overview, Setup, and Chassis Management

2. Enter the IP Address of the workstation that is to receive traps. IP
address entries must follow the DDN format (nnn.nnn.nnn.nnn).
3. Press ENTER. If an invalid entry is entered "INVALID IP
ENTERED" is displayed in the Event Message Line.
4. Using the arrow keys, highlight the Trap Community Name field.
Enter the community name.
5. Press ENTER.
6. Using the arrow keys, highlight the Enable Traps field. Press the
SPACE bar to choose either YES (send alarms from the chassis to the
workstation), or NO (prevent alarms from being sent).
7. Using the arrow keys, highlight the SAVE command and press
ENTER. The message "SAVED OK" displays on the screen. The
designated workstations now receive traps from the DLM6C-AA.
Exiting without saving causes a "NOT SAVED?" message to
appear in the Event Message Field. Edits will be lost if they are
not saved before exiting.

5.11 CHASSIS ENVIRONMENTAL SCREEN

The Chassis Environmental menu item allows the user to view chassis
environmental information.
To access the Chassis Environmental Information screen from the Chassis
Menu screen, use the arrow keys to highlight the CHASSIS
ENVIRONMENTAL menu item and press ENTER. The Chassis
Environmental Information screen, Figure 5-11, displays.