After changing the position of switch 6 and restarting the module, the
DLE02-MA and the DLE52-MA request a new image download until
they either receive a new image or the RESET button on the front panel
is pressed. When the RESET button is pressed, the DLE02-MA and
the DLE52-MA continue trying to contact a BootP server, but will time
out in approximately one minute. If the module times out, the image is
downloaded from its FLASH memory.
Switch 7 – Clear NVRAM. Changing the position of this switch resets
NVRAM on the next power up. ALL user entered parameters, such as
IP addresses, subnet masks, SNMP traps, and switching functions are
restored to their factory default settings.
Switch 8 – Reset Password/Community Strings. Changing the position
of this switch clears only the user-entered passwords stored in
NVRAM, and restores the default passwords. Once the DLE02-MA
and the DLE52-MA reset, the passwords can either be reentered or the
default passwords (Public and ENTER) may be used.
Do not change the position of switch 8 unless it is necessary to
reset the module super-user configured passwords to their
factory default settings.
DLE02-MA/DLE52-MA User's Guide

Setting the Mode Switches

B-3