Table 4-6 Management System Troubleshooting (Continued)
Possible Causes
The DLE02-MA or
the DLE52-MA
does not have an
IP address.
The applicable
front panel port is
disabled.
DLE02-MA/DLE52-MA User's Guide
Instruction
1. Refer to Section 6.4.1 for IP address assignment
procedure.
2. If the DLE02-MA and the DLE52-MA are using the IP
address of the DLM6C-AA chassis, ensure that the
modules are not in STANDALONE management
mode. Section 6.4.9 provides instructions on setting
the management mode.
1. Enable port. Refer to Section 6.16.3 for instructions
on enabling/disabling ports.
2. Port may disabled due to Spanning Tree. Review
network design and delete unnecessary loops.
Troubleshooting Checklist
4-9