Chapter 3
Installation

representative. Refer to the Getting Help section in the Preface of this
Guide.
To prevent damaging the backplane connectors in the following
!
step, take care that the module slides in straight and properly
engages the backplane connectors.
Ensure that the top plastic locking tab lines up with the desired
slot number located on the front panel of the chassis. Refer to
Figure 3-1.
6. Locate the slot guides that line up with the number of the slot in which
the module will be installed. Install the module in the chassis by
aligning the module circuit card between the upper and lower metal
rail guides of the desired slot, sliding it into the chassis, and locking
down the top and bottom plastic locking tabs, as shown in Figure 3-1.
Take care that the module slides in straight and properly engages the
backplane connectors.
7. If the chassis in which the module is installed was powered down for
the installation, turn it back on. Check to see that the CPU LED settles
at solid green after a few minutes. If the LED does not turn solid green,
see Chapter 4 for details.
3.4

CONNECTING TO THE NETWORK

This section provides the procedures for connecting twisted pair segments
from the network or other devices to the DLE02-MA or the DLE52-MA.
If the DLE02-MA and the DLE52-MA are being installed in a
network using SmartTrunking, there are rules concerning the
network cable and port configurations that must be followed for
SmartTrunking to operate properly. Refer to the list of
supported features in the release notes to determine if
SmartTrunk is supported. Before connecting the cables, refer to
the SmartTrunk User's Guide for the configuration information.
3-4
DLE02-MA/DLE52-MA User's Guide