Chapter 5
LM: Overview, Setup, and Chassis Management

5.3.3

Telnet Connections

Once the module or chassis has a valid IP address, the user can establish a
Telnet session with Local Management from any TCP/IP based node on
the network. Telnet connections to the DLE02-MA and the DLE52-MA
require the community name passwords assigned at the SNMP
Community Names screen of either the DLM6C-AA chassis, or the
module.
For information about setting the IP address, refer to Section 5.8.
For information about assigning community names, refer to Section 5.9.
Refer to the instructions included with the Telnet application for
information about establishing a Telnet session.
If the DLE02-MA or the DLE52-MA is operating in the 802.1Q mode,
the management station must be connected to a physical port on the
device that is on the same VLAN as the virtual Host Data Port. For more
information about the virtual Host Data Port and the setup information for
remote management in a device that is to be configured with VLANs,
refer to the Port Based VLAN User's Guide.
5.3.4

Monitoring an Uninterruptible Power Supply

If the DLM6C-AA chassis is connected to an American Power
Conversion (APC) Uninterruptible Power Supply (UPS) for protection
from a loss of power, a connection from the COM port of a module to the
UPS can be made to monitor the status of the UPS. To use the COM port
for this purpose, it must be reconfigured to support the UPS application.
This procedure is performed from the General Configuration screen of the
interface module. Section 6.4.10 provides detailed instructions on
configuring the COM port for UPS applications. Refer to the UPS
documentation for details on how to access the status information.
Use the Console Cable Kit provided with the DLM6C-AA chassis to
attach the UPS to the module COM port as shown in Figure 5-2.
Connect the UPS device to the COM port of the DLE02-MA or the
DLE52-MA as follows:
1. Connect the RJ45 connector at one end of the cable to the COM port
on the module.
5-6
DLE02-MA/DLE52-MA User's Guide